Communication Manager Maintenance-Object Repair Procedures
1470 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1019
ABRT
Another Test call is in progress.
1. Enter list isdn-testcall to locate the test call.
2. Enter status isdn-testcall to find out the duration and start time 
of the test call.
3. Enter clear isdn-testcall to stop the test call from running.
4. If time and duration indicate that the test call should have stopped, and 
clear isdn-testcall does not work, see
strategy.
1020
ABRT
There is a problem with the DS1 Interface circuit pack.
1. See 
1024
ABRT
(M/T-DIG) Maintenance/Test Digital Port in use.
1. Wait until yellow and green LEDs are turned off on the M/T-BD 
(Maintenance/Test circuit pack).
2. Retry test. If problem persists, see
1113
ABRT
The signaling link has failed. Therefore, the system cannot send any 
messages on behalf of this trunk.
1. Check the results of the Signaling Link State Check test (#255).
1116
ABRT
The switch could not appropriately change the ISDN service state.
1. Enter status trunk grp#/mem# to determine whether a call is 
active on this DS1 ISDN trunk. If so, proceed as for Error Code 1119.
2. If not, check the Error and Alarm Logs for problems with this 
ISDN-TRK (DS1 ISDN Trunk) MO.
1117
ABRT
ISDN Service message is already outstanding.
1. Wait 2 minutes. Then try again.
Table 530: Test #258 ISDN Test Call  (continued)
Error 
Code
Test 
Result
Description / Recommendation