Avaya 03-300430 User Manual

Page of 2574
MAPD-BD (MAPD Interface Circuit Pack TN802)
Issue 1 June 2005
1511
 
Note:
Note:
Local restore of a complete system from the PCMCIA disk should not require 
more than 20 minutes assuming that a replacement MAPD pack is available and 
pre-loaded with the IP trunk application software.
Restoring Data from the PCMCIA Disk
Before You Start
1. Shut down the application running on the circuit pack. See 
2. Remove the defective IP Trunk circuit pack from the switch (if applicable).
3. Install the replacement IP Trunk circuit pack in the switch (if applicable).
4. Insert the backup diskette into the IP Trunk circuit pack.
5.
Wait
Backup can take as much as 20 minutes to complete.
6.
Release circuit pack
At the S8700 Media Server terminal, type release board 
location (the address of the TN802 circuit pack), and press 
Enter.
Table 545: Backing up TN802 administration data  (continued)
Step
Description
Comments
 2 of 2
Table 546: Restore TN802 administration data 
Step
Description
Comments
1.
Restore IP 
Trunk 
administration
At the Windows 2000 desktop, double-click on the IP Trunk 
Backup/ Restore icon.
The IP Trunk Backup/Restore Utility screen appears.
2.
Select utility
In the IP Trunk Backup/Restore Utility dialog screen, click Files> 
Restore.
The IP Trunk Backup screen appears.
3.
Select restore
In the IP Trunk Backup screen, click on the Restore button.
4.
Wait
Wait until the amber Disk-In-Use LED (Note 5 in