Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1552 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Be physically inserted into the correct slot
If the circuit pack has an entry on the circuit pack screen and any of the other conditions are 
not met, a MINOR alarm is logged. To resolve the error:
Make sure every condition for administration is met, and that a functioning Media 
Resource is inserted in the correct slot.
Completely remove the IP Media Resource from the system:
a. Remove the administered IP-Interface associated with the circuit pack.
b. Physically remove the circuit pack from the slot.
b. Error Type 1000210012: Simplex mode downlink. The reason for the state interchange to 
active was a Simplex mode downlink to the circuit pack. When the board is inserted and 
before it is used for any bearer traffic, the server configures the board to operate either in 
Simplex or Duplex mode via a downlink message. That operation may trigger the 
interchange.