Avaya 03-300430 User Manual

Page of 2574
MG-DS1 (DS1 Interface Media Module)
Issue 1 June 2005
1617
 
1
FAIL
The test failed. The MM710 interface Media Module detected a loss of 
multiframe alarm (LMA). An out of frame condition occurred on the 
MM710 interface Media Module. The MM710 interface Media Module will 
transmit a remote multiframe alarm (RMA) to the remote MM710 endpoint 
until the LMA is retired.
If the MM710 connects to a T1 network facility or to another switch, do 
the following:
1. Verify that both endpoints of the DS1 link are administered using the 
same signaling mode, framing mode, and line coding.
2. Check the physical connectivity of the MM710 packs and of the 
cable.
3. Replace the local MM710 interface Media Module, and repeat the 
test.
4. Contact T1 Network Service or a technician at the far-end switch to 
diagnose the remote DS1 endpoint.
If the MM710 connects to a line-side terminating device (for example, a 
PRI terminal adapter), do the following:
1. Verify that the switch DS1 and the line-side terminating device are 
administered using the same signaling mode, framing mode, and 
line coding.
2. Investigate the maintenance status of the line-side terminating 
device. Refer to the 'Line-Side Terminating Device Operating 
Manual' for information.
3. Check the physical connection of the MM710 interface Media 
Module to the terminating device, and check the premise distribution 
system (or the intra-premise wiring) for physical connection failures.
4. Replace the local MM710 interface Media Module and repeat the 
test.
5. Contact the vendor of the line-side terminating device to diagnose 
the equipment.
Table 594: TEST #140 Red Alarm Inquiry Test  (continued)
Error
Code
Test
Result
Description/ Recommendation