Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1626 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
FAIL
The performance of the DS1 link between the MM710 interface Media 
Module and the remote DS1 endpoint is very poor. Enter the list 
measurement ds1-log location command to read the error 
seconds measurement.
If the MM710 connects to a T1 network facility or to another switch, do 
the following:
1. Verify that both endpoints of the DS1 link are administered using the 
same signaling mode, framing mode, and line coding. 
2. Check the physical connectivity of the MM710 interface Media 
Modules and the cable.
3. Replace the local MM710 interface Media Module, and repeat the 
test.
4. Contact T1 Network Service or the technician at the remote switch to 
diagnose the equipment.
FAIL
(
cont’d
)
If the MM710 connects to a line-side terminating device (for example, a 
PRI terminal adapter), do the following:
1. Verify that the switch DS1 and the line-side terminating device are 
administered using the same signaling mode, framing mode, and line 
coding.
2. Investigate the maintenance status of the line-side terminating 
device. Refer to the 'Line-Side Terminating Device Operating 
Manual' for information.
3. Check the physical connection of the MM7101 interface Media 
Module to the terminating device, and check the premise distribution 
system (or the intra-premise wiring) for physical connection failures.
4. Replace the local MM710 interface Media Module and repeat the 
test.
5. Contact the vendor of the line-side terminating device to diagnose 
the equipment.
 
PASS
No Major alarm is detected in the MM710 Interface Media Module.
Table 596: TEST #142 Major Alarm Inquiry Test  (continued)
Error
Code
Test
Result
Description/ Recommendation
 2 of 3