Avaya 03-300430 User Manual
Denial Event Tables
Issue 1 June 2005
183
1083
Add/Rmv skill denied
Add/Remove Agent Skills. Possible causes:
●
could not get station ID
●
too many admin users or
save-translations in progress
save-translations in progress
●
data already locked, maybe translations
are being saved or SAT user is changing
agent data
are being saved or SAT user is changing
agent data
1084
DCS link down
Remote user activation of call forward -
Distributed Communication System (DCS) link not
up.
1085
PMS response timeout
Property Management System failed to respond
to maid status in the 4 seconds allowed.
1086
MFC no answer timeout
MultiFrequency Compelled (MFC) call circuit
congestion. No answer timeout from MFC call.
1087
MFC no answer timeout
MultiFrequency Compelled call circuit congestion.
No answer timeout. Might be bad trunk or no
Touch Tone Receiver (TTR) available at remote
end, for example.
1088
No answer timeout
MultiFrequency Compelled call circuit congestion.
No answer timeout. Might be bad trunk or no
Touch Tone Receiver (TTR) available at remote
end, for example.
1089
MFC no answer timeout
MultiFrequency Compelled call circuit congestion.
No answer timeout. Might be bad trunk or no
Touch Tone Receiver (TTR) available at remote
end, for example.
1090
T302 intercept timeout
T302 interdigit timer timeout.
1091
Max Paste users Pasting
The maximum allowable stations are currently
using PC Application Software Exchange
(PASTE). Wait and try again.
1092
Announcement unavailable
Might be announcement is busy, or
announcement is not present on board.
1093
Announcement memory exh
Announcement is dropped, announcement
memory is exhausted.
1094
Permanent Seizure
Direct Inward Dialing trunk origination. Digit
timeout with no digits dialed. Permanent incoming
seizure treatment is to give reorder.
1095
QSIG Call Offer timeout
QSIG Call Offer encountered timeout of 1 minute
path retention timer.
1096
Wakeup time unavailable
Collecting digits for “room wakeup by tones”
feature. Cannot do a wakeup for the specified
time.
1097
MFC No Answer timeout
MFC call circuit congestion. No answer timeout.
Might be bad trunk or no Touch Tone Receiver
(TTR) available at remote end, for example.
Table 48: Call Process denial events (1001 - 1172) (continued)
Event
Type
Type
Event Description, as it
appears on the event log
appears on the event log
Explanation
Event
Data 1
Data 1
Event Data 2
7 of 13