Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1864 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Notes:
a. Error Type 0: an error took place in generating the Error Code.
b. Error Type 10000-10063: a spontaneous PNC interchange took place in response to the 
retiring of an alarm on the A-PNC associated with fault class FC_EAL. Use status pnc to 
look at the state of health indexes for the PNCs, and investigate any associated alarms. 
Adding 1 to the last two digits of the Error Code gives the PN number of the port network 
that reported the retired alarm. (10003 points to port network 4) Use list config 
port-network
 to show the cabinet number associated with a port network.
c. Error Type 10100-10163: a spontaneous PNC interchange took place in response to the 
retiring of an alarm on the A-PNC associated with fault class FC_INL. Use status pnc to 
look at the state of health indexes for the PNCs, and investigate any associated alarms. 
Adding 1 to the last two digits of the Error Code gives the PN number of the port network 
that reported the retired alarm. (10003 points to port network 4)Use list config 
port-network
 to show the cabinet number associated with a port network.
d. Error Type 10200-10263: a spontaneous PNC interchange took place in response to the 
retiring of an alarm on the A-PNC associated with fault class FC_HW. Use status pnc to 
look at the state of health indexes for the PNCs, and investigate any associated alarms. 
Adding 1 to the last two digits of the Error Code gives the PN number of the port network 
that reported the retired alarm. (10203 points to port network 4.) Use list config 
port-network
 to show the cabinet number associated with a port network.
e. Error Type 10300-10363: a spontaneous PNC interchange took place in response to the 
retiring of an alarm on the A-PNC associated with fault class FC_PER. Use status pnc to 
look at the state of health indexes for the PNCs, and investigate any associated alarms. 
Adding 1 to the last two digits of the Error Code gives the PN number of the port network 
that reported the retired alarm. (10303 points to port network 4.) Use list config 
port-network
 to show the cabinet number associated with a port network.
11701 – 11764 (
)
1
53000 (
1
20000 – 20063 (
1
60801 (
)
1
20100 – 20163 (
1
60800 (
)
1
1. The Aux Data indicates which PNC became active after the PNC interchange: “0” 
denotes PNC-A; “1” denotes PNC-B.
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
18
None
busyout pnc-dup
WRN
ON
release pnc-dup
Error Type
Aux Data
Error Code
Aux Data