Avaya 03-300430 User Manual

Page of 2574
PNC-DUP (PNC Duplication)
Issue 1 June 2005
1867
 
t. Error Type 20300 – 20363: a spontaneous PNC interchange took place in response to the 
retiring of an alarm on the B-PNC associated with fault class FC_PER. Use status pnc to 
look at the state of health indexes for the PNCs, and investigate any associated alarms. 
Adding 1 to the last two digits of the Error Code gives the PN number of the port network 
that reported the retired alarm. (20303 points to port network 4.) Use list config 
port-network
 to show the cabinet number associated with a port network.
u. Error Type 20400 – 20463: a spontaneous PNC interchange took place in response to the 
retiring of an alarm on the B-PNC associated with fault class FC_DS1. Use status pnc to 
look at the state of health indexes for the PNCs, and investigate any associated alarms. 
Adding 1 to the last two digits of the Error Code gives the PN number of the port network 
that reported the retired alarm. (20403 points to port network 4.) Use list config 
port-network
 to show the cabinet number associated with a port network.
v. Error Type 20500 – 20563: a spontaneous PNC interchange took place in response to the 
retiring of an alarm on the B-PNC associated with fault class FC_BFD. Use status pnc to 
look at the state of health indexes for the PNCs, and investigate any associated alarms. 
Adding 1 to the last two digits of the Error Code gives the PN number of the port network 
that reported the retired alarm. (20203 points to port network 4.) Use list config 
port-network
 to show the cabinet number associated with a port network.
w. Error Type 20600 – 20664: a spontaneous PNC interchange took place in response to the 
retiring of an alarm on the B-PNC associated with fault class FC_SNIL. Use status pnc to 
look at the state of health indexes for the PNCs, and investigate any associated alarms. The 
last two digits of the Error Code indicate the fiber-link number (01-27) of the fiber that 
reported the retired alarm. Use list fiber-link to show the location of the fiber.
x. Error Type 20700 – 20764: a spontaneous PNC interchange took place in response to the 
retiring of an alarm on the B-PNC associated with fault class FC_SNIHW. Use status pnc 
to look at the state of health indexes for the PNCs, and investigate any associated alarms. 
The last two digits of the Error Code indicate the fiber-link number (01-27) of the fiber that 
reported the retired alarm. Use list fiber-link to show the location of the fiber.
y. Error Type 21000-21063: a spontaneous PNC interchange took place in response to the 
occurrence of a major or minor alarm on the B-PNC associated with fault class FC_EAL. 
This indicates that one or more Expansion Archangel Links are down. Investigate any 
EXP-PN alarms. Adding 1 to the last two digits of the Error Code gives the PN number of 
the port network that reported the alarm. (21003 points to port network 4.) Use list 
config port-network
 to show the cabinet number associated with a port network.
z. Error Type 21100-21163: a spontaneous PNC interchange took place in response to the 
occurrence of a major or minor alarm on the B-PNC associated with fault class FC_INL. 
This indicates that one or more neighbor or indirect neighbor links with an EI as an endpoint 
have experienced faults. Investigate any alarms against EXP-PN and SN-CONF. Adding 1 
to the last two digits of the Error Code gives the PN number of the port network that 
reported the alarm. (21103 points to port network 4.) Use list config port-network 
to show the cabinet number associated with a port network.