POW-SUP (power supply)
Issue 1 June 2005
1887
 
1973
ABRT
The carrier does not contain a redundant power supply.
1977
ABRT
There is an active Expansion ArchAngel (EAA) in the carrier that a recycle 
was attempted on. Recycling the carrier with the active EAA will result in 
loss of network control to the entire port network. 
1. If the TN2312 IPSI circuit packs are duplicated, move network control 
to the other carrier (IPSI) using the following commands:
list ipserver-interface to verify that the IPSI in the carrier 
of interest is active. 
set ipserver cabinet a or to move the control to the other 
IPSI. 
recycle carrier cabinet a or to recycle the carrier.
2. If the TN2312 IPSI circuit packs are not duplicated. 
Enter recycle carrier override to recycle the carrier. 
1980
ABRT
The power supply is in a carrier with an active expansion interface (EI).
1. Use the status port-network nn to verify that the EI (A or B) in 
the carrier of interest is active.
2. Enter reset pnc interchange to move port network connectivity 
to the other expansion interface. 
3. Enter recycle carrier again 
2000
ABRT
The response to a query was not received in the time allowed. 
1. Repeat the command at one-minute intervals 1 to 3 times.
2028
ABRT
There is a problem communicating with the environmental maintenance 
firmware.
2100
ABRT
The system could not allocate resources.
1. Repeat the command at one-minute intervals 1 to 3 times.
2319
ABRT
The EPN is out of range.
2500
ABRT
An internal operation failed
1. Retry the command.
Table 688: Power supply recycle test (#1534) (continued)
Error
code
Test
result
Description and recommendation
 2 of 3