Avaya 03-300430 User Manual
SNI-BD (SNI Circuit Pack)
Issue 1 June 2005
2049
Remote PNs
A DS1 converter complex can used to provide connectivity to a remotely located port network.
The DS1 converter complex consists of two TN574 DS1 converter (DS1C) circuit packs
connected by 1 to 4 DS1 facilities. The DS1C complex is administered as a fiber link.
The DS1 converter complex consists of two TN574 DS1 converter (DS1C) circuit packs
connected by 1 to 4 DS1 facilities. The DS1C complex is administered as a fiber link.
Figure 120: Fiber Link over a DS1 Converter Complex
SNI LEDs
The SNI circuit pack has red, green, and yellow LEDs. The red and green LEDs have the usual
meaning, with red signifying an on-board alarm, and green signifying maintenance testing in
progress. The red and green LEDs will come on and then turn off when the circuit pack is reset.
meaning, with red signifying an on-board alarm, and green signifying maintenance testing in
progress. The red and green LEDs will come on and then turn off when the circuit pack is reset.
Note:
Note:
If the red LED is on without any alarms active against the circuit pack, replace the
SNI circuit pack. This indicates that SNI firmware has detected a fault and is
unable to notify software.
SNI circuit pack. This indicates that SNI firmware has detected a fault and is
unable to notify software.
The yellow LED indicates status information:
metallic connection
or
optical fiber
metallic connection
or
optical fiber
1 to 4 DS1 Facilities
TN570
TN574
TN574
TN573
SNI
DS1C DS1C
EI
Table 747: SNI Yellow LED states
Condition
LED on
LED off
Fiber out of Frame
0.1 second 0.1 second
In frame, No Neighbor
1
1. The fiber is in frame but a communication problem
exists to the neighbor.
0.5 second 0.5 second
SNI active
solid on
never off
SNI standby
never on
solid off