Avaya 03-300430 User Manual

Page of 2574
SNI-BD (SNI Circuit Pack)
Issue 1 June 2005
2083
 
112
FAIL
The SNI circuit pack cannot communicate with the active SNC.
1. Check the error log for other SNI circuit packs in the same carrier with 
a 257 SNI-BD error. Use display errors with category PNC to 
view SNI-BD errors. If other SNI circuit packs in the same switch node 
carrier have error 257, then replace the active SNC in this switch node 
carrier. Replacing an SNC may be service interrupting. See 
on page 2000 for the procedure for 
replacing an SNC. If other SNI circuit packs in the same carrier do not 
have SNI-BD Error Type 257 logged, proceed to step 2.
2. Replace this SNI. Replacing an SNI may be service interrupting. See 
on page 2046 for the procedure for 
replacing an SNI.
3. Replace the active SNC in the same switch node carrier. Replacing an 
SNC may be service interrupting. See 
on page 2000 for the procedure for replacing an SNC.
113
FAIL
The SNI circuit pack cannot communicate with the equipped SNI in slot 
13.
1. Perform the 
 procedure in Maintenance 
Procedures (03-300192). This will resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 2049, replace the 
SNI being tested. Replacing an SNI may be service interrupting. See 
on page 2046 for the procedure for 
replacing an SNI. To view SNI-PEER errors, use display errors 
with category PNC-PEER. Retry the command.
3. If the SNI being tested has SNI-PEER Error Type 2049, replace the 
SNI in slot 13. Replacing an SNI may be service interrupting. See 
on page 2046 for the procedure for 
replacing an SNI. Retry the command.
Table 752: TEST #759 Configuration Audit  (continued)
Error
Code
Test
Result
Description / Recommendation
 7 of 13