SYS-PRNT (System Printer)
Issue 1 June 2005
2183
 
See 
on page 2181 for recommended 
maintenance strategy.
c. Error Type 513: the SYS-PRNT was interrupted for one of the following reasons:
The cable to the SYS-PRNT output device is disconnected
The SYS-PRNT output device is powered off
The data extension to which the SYS-PRNT output device connects has been busied out
Internal software error
Check the connectivity of the wires and cables among the wall jacket, data module, and 
SYS-PRNT output device. Follow the instructions in 
System-Technician-Demanded Tests: Descriptions And Error 
Codes
Investigate tests in the order presented below. Clearing error codes associated with the one test 
may also clear errors generated from other tests in the sequence.
Table 777: Aux Data, Error Type 257
Aux
Data
Description
1
No C-LAN port available. See 
3, 4
Time-out during setup attempt. Most likely due to problem with physical link 
or printer status.
5
Internal system error. Most likely temporary/sporadic failure.
2, 6
The data module the printer is trying to use is busy with another call. Use 
status data module to determine when the port is available for testing.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
Link Tear Down test (#213)
X
D
Link Retry test (#215)
X
X
ND