Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
2404 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Table 857: Test #135 Internal Loop-Around Test 
Error
Code
Test
Result
Description / Recommendation
1002
ABRT
The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions or it may have time slots out-of-service due 
to TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic, 
repeat test at 1-minute intervals up to 5 times.
1003
ABRT
The system could not allocate a tone receiver for the test. The system 
may be oversized for the number of Tone Detectors present or some Tone 
Detectors may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry reset board location at 
1-minute intervals up to 5 times.
1004
ABRT
Received an incoming call on a port of the UDS1 circuit pack during the 
test.
1. Enter busyout board location to put every trunk or port of the 
UDS1 Interface circuit pack in the out-of-service state.
2. Retry reset board location at 1-minute intervals up to 5 times.
1015
ABRT
Ports on the UDS1 Interface circuit pack have not been busied out.
1. Enter busyout board location to put every trunk or port of the 
UDS1 Interface circuit pack into the out-of-service state.
2. Retry reset board location.
1039
ABRT
The UDS1 Interface circuit pack is providing timing for the system. 
Executing this test could cause a major system disruption.
If the UDS1 Interface circuit pack needs to be tested, set the 
synchronization reference to another UDS1 Interface circuit pack or to the 
IPSI or Tone-Clock circuit pack via the following command sequence:
1. Enter disable synchronization-switch.
2. Enter set synchronization location.
3. Enter enable synchronization-switch.
2000
ABRT
Response to the test request was not received within the allowable time 
period. If Error Type 1538 is present in the Error Log, follow the 
maintenance strategy recommended for this Error Type.
 1 of 4