UDS1-BD (UDS1 Interface Circuit Pack)
Issue 1 June 2005
2473
 
If the 120A1 CSU module or the 401A T1 sync splitter is not physically installed, the status 
LEDs are always off and this test aborts.
Table 875: Test #1227 ICSU Status LEDs Test 
Error
Code
Test
Result
Description / Recommendation
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1005
ABRT
The ICSU Status LEDs test cannot be executed for the current 
configuration. The test applies only to TN464F or later UDS1 circuit packs 
administered for 24-channel (1.544-Mbps) operation.
2. If the circuit pack is a TN464F or higher suffix UDS1 circuit pack, then 
retry the command.
1951
ABRT
The ICSU Status LEDs test cannot be executed because a 120A1 or higher 
suffix CSU module or a 401A or higher suffix T1 sync splitter is not 
physically installed. If using a 120A1 CSU module or the 401A T1 sync 
splitter, physically connect it to the UDS1-BD board on the back of the port 
carrier. Otherwise, ignore this abort.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2500
ABRT
Internal system error.
1. Retry the command.
 
PASS
The ICSU Status LEDs test executed successfully. A PASS result, 
however, does not necessarily mean that the status LEDs behaved 
properly. It only means that the software successfully attempted to light the 
status LEDs. This is a visual test. The service technician must visually 
examine the behavior of the LEDs while the test is running. The LEDs are 
functioning properly if the four status LEDs are lit red for 5 seconds, then lit 
green for 5 seconds, then lit yellow for 5 seconds. If the LEDs behave 
differently, the board should be replaced at the customer’s convenience.