Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
2486 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Notes:
a. Error Type 1: circuit pack stopped functioning or is not physically present.
1. Verify that the circuit pack is present.
2. If circuit pack is present, reset the circuit pack (reset board location).
3. If the error persists, replace the circuit pack.
b. Error Type 18: the VAL circuit pack is busied out.
c. Error Type 217: applies to 10 circuit packs:
1. Remove the circuit pack(s) against which the error is logged.
d. Error Type 257: transient communication problem between switch and circuit pack; does 
not affect service and can be ignored.
1. Ignore this error, unless the Control Channel Loop test (#52) fails.
2. If Test #52 fails, replace the circuit pack.
Repetitive failures of the Control Channel Loop test indicate circuit pack hardware failure.
3841,
3843 (
3842 (
Receive FIFO Overflow Error 
Counter test (#596)
3844 (
Any
3845 (
Any
3846 (
Any
3848 (
Any
3851 (
Any
3852 (
Any
3853 (
Any
3854 (
Any
3855 (
Any
3856 (
Any
Table 879: VAL Hardware Error Log entries  (continued)
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
 2 of 2