VC DSP Port Local TDM Loop-Back Test (#1104)
This test is destructive.
This test verifies the connectivity of a VC DSP Port across the TDM bus. It aborts if calls 
associated with the port are in progress. Failure of this test indicates an on-board fault 
associated with the port hardware on the circuit pack. The Loopback test runs the following 
tests:
1. A loop-around test across the TDM bus.
2. A conference circuit test.
The tests are run in the above order; if one test fails, an Error Code is returned and the 
remaining tests in the sequence are not executed.
Table 892: Test #1103 NPE Crosstalk Test 
Error
Code
Test
Result
Description / Recommendation
1000
1001
ABRT
System resources required to run this test are not available. The port may 
be busy with a valid call.
1. Retry the command at 1-minute intervals up to 5 times.
2012
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary resources for this test.
1. Retry the command at 1-minute intervals up to 5 times.
0-3
FAIL
The NPE of the tested port was transmitting in error, causing noisy and 
unreliable connections.
1. Replace the circuit pack.
PASS
The port is correctly using its allocated time slots.
1. To be sure that this is not an intermittent problem, repeat this test up to 
10 times.