Avaya 03-300430 User Manual

Page of 2574
VC-SUMPT
Issue 1 June 2005
2529
 
1002
ABRT
The system could not allocate time slots for the test. The traffic load on the 
system is very high, or time slots are out-of-service due to TDM-BUS 
errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic, 
retry the command at 1-minute intervals up to 5 times.
1003
ABRT
The system could not allocate a Tone Detector for the test, the system is 
oversized for the number of Tone Detectors present, or some Tone 
Detectors are out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up 
to 5 times.
1004
ABRT
The port has been seized by a user for a valid call. Use status station 
for the station associated with this port to determine whether the port is 
available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
2000
ABRT
Response to the test request was not received from the VC-BD circuit 
pack within the allowable time period.
1. If this result occurs repeatedly, reset the circuit pack if the other ports 
are idle. Reset the circuit pack by issuing busyout board 
location
 and reset board location.
2. If this result occurs again, replace the circuit pack.
2012
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2103
ABRT
The system could not make the conference connection for the test.
1. Retry the command at 1-minute intervals up to 5 times.
0
FAIL
The TDM Loop-Around test failed.
Table 899: Test #1100 VC Summer Port Local TDM Loop-Back Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 3