MM710 T1/E1 Media Module LEDs
The T1/E1 Media Module has four LEDs on its faceplate (see 
on page 297 shows their color and functions. The 
first three are the standard LEDs, which are under software control.
Figure 20: T1/E1 Media Module LEDs
Table 82: T1/E1 LEDs
Name Color
Location
Description
ALM
RED
Top
Upon power-up, this LED is turned on. Upon passing 
diagnostics this LED is turned off. During normal circuit pack 
operation this LED is not turned on except for certain alarm 
states.
TST
GREEN
Second
During power-up self-testing and maintenance testing 
requested by the SPE, this LED is turned on.
ACT
YELLOW Third
This LED indicates that the clock is synchronized with a 
source (usually the Central Office). The LED is blinking 2700 
ms ON and 300 ms OFF. This is the most common condition.
The opposite blinking of the YELLOW LED is 300 ms ON and 
2700 ms OFF. This is an error condition, and indicates that 
the MM710 T1/E1 Media Module is not synchronized with a 
clock.
An infrequent occurrence is a steady YELLOW LED. This 
indicates in-use activity, only when clock synchronization is 
set to local.
SIG
GREEN
Bottom
This LED indicates whether the link to the Central Office (CO) 
is up (equivalent to the TN464 circuit pack Status 3 GREEN 