Avaya 03-300430 User Manual

Page of 2574
ADX8D-PT (AUDIX Digital Port)
Issue 1 June 2005
345
 
ADX8D-PT (AUDIX Digital Port)
S8700 | 8710
 / 
S8500
The ADX8D-PT MO represents a port on a TN566/TN2169 EMBEDDED AUDIX circuit pack 
(also called DEFINITY AUDIX) operating in DP (digital-port) mode. The maintenance strategy 
for ports on the TN566 operating in control-link mode is described in ADX16A-PT.
The tests described in this section apply only to switch-side maintenance that tests a circuit 
pack’s components related to the TDM-bus interface. The AUDIX system has an extensive 
maintenance strategy that is described in EMBEDDED AUDIX System Maintenance, 
585-300-110
.
AUDIX resides on a combined pair of circuit packs: the TN566 MFB (multifunction board) and 
the TN2169 ALB (alarm board). Because of its size, this combination occupies 5 slots, but only 
1 slot is functional as far as the switch is concerned. The other 4 slots are seen by the switch as 
“AUDIX-reserved” slots (or ADXDP-RS/ADX8D-RS).
In DP mode the TN566 pack supports up to 8 voice ports, each with a primary and a secondary 
information channel. Ports are administered in increments of two. When a call to a station with 
an AUDIX login is not answered, AUDIX answers the call using one of the available voice ports.
Unlike other AUDIX systems, EMBEDDED AUDIX is not an adjunct.
!
CAUTION:
CAUTION:
Never do any of the following without first shutting down AUDIX. Follow 
instructions on the TN566/TN2169 faceplate:
Remove EMBEDDED AUDIX circuit packs
Cycle power to a carrier containing EMBEDDED AUDIX circuit packs
Remove power to a carrier containing EMBEDDED AUDIX circuit packs
MO Name in Alarm Log Alarm 
Level
Initial Command to Run
Full Name of MO
ADX8D-PT
MIN
test port location l
AUDIX digital port
ADX8D-PT
WRN
test port location sh
AUDIX digital port