Avaya 03-300430 User Manual
Communication Manager Maintenance-Object Repair Procedures
510 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 0: Run the short test sequence first. If every test passes, run the long test
sequence. Refer to each appropriate test’s description, and follow its recommended
procedures.
procedures.
b. Error Type 1: the two ends of the ATM trunk do not agree on the ISDN call state. Possible
causes:
●
Received a DISConnect or RELease COMplete message with cause value 52 (outgoing
calls barred)
calls barred)
●
Received a DISConnect or RELease COMplete message with cause value 54 (incoming
calls barred)
calls barred)
Table 159: ATM-BCH Error Log entries
Error
Type
Type
Aux
Data
Data
Associated Test
Alarm
Level
Level
On/Off
Board
Board
Test to Clear Value
0 (
)
0
Any
Any
Any
test port location
1(
Any
None
test port location
18
0
busyout trunk grp/
mbr
release trunk grp/mbr
129 (
None
WRN
OFF
test port location
130 (
)
test port location
257(
)
Any
Service State Audit test
(#256)
test port location
513(
)
Any
None
WRN
OFF
test port location
769(
)
Any
Service State Audit test
(#256)
test port location
1793
Any
None
test port location
3073(
Any
Service State Audit test
(#256)
test port location
3585(
Any
None
none
3841
)
Any
None
WRN
OFF
none