Avaya 03-300430 User Manual

Page of 2574
Server Alarms
54 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Back to:              
             
DAJ1/DAL1 Alarms in S8700 Media Server
S8700 | 8710
 only
on page 54 describes the Duplication Memory 
card MO’s alarms and their troubleshooting procedures.
Table 12: TEST DAJ1/DAL1 Local Loop Test 
 Error Code
Test Result
Description / Recommendation
Open failed 
to MDD
ABRT
The MDD is the system driver that communicates with the 
Duplication Memory board. If this driver cannot be opened, the 
board’s registers cannot be read.
This is a system type error, try again.
System Error 
MDD failed 
to return 
data
ABRT
The test ran, but for some reason the MDD could not return 
data.
This is a system type error, try again.
Loop-around 
test failed
FAIL
The last address received does not match the address that was 
written, or the last data received does not match the data that 
was written.
Table 13: DAJ1/DAL1 Alarms in Media Server 
Event
ID
Alarm
Level
Alarm Text, Cause/Description, Recommendation
2
WRN
“Single-bit EDC test (bad SB err cnt)” — Single-bit SDRAM error occurred 
20 times.
Software automatically clears the single-bit error register. This is a 
log-only indication of the error’s occurrence.
1. Manually clear the alarm, either from the:
- Web interface, by selecting Alarms and Notification, the 
appropriate alarm, and Clear
- Linux command line, by entering almclear -n #id
 1 of 2