ATM Board Error Query Test (#1259)
This test is nondestructive.  The ATM circuit pack firmware maintains counters for some of the 
on- and off-board errors.  The maintenance software queries the board for its health information 
to do error analysis.  These alarms have assigned priority: if a higher priority alarm occurs, the 
remaining alarms are not reported to the software (through the inline errors), avoiding 
unnecessary up-link, in-line error message traffic.  This is run as a part of a craft demand test 
sequence periodic testing, initialization, and error analysis.
Table 178: ATM Board Error Query Test (#1259) 
Error 
Code
Test 
Result
Description / Recommendation
2000
ABRT
Response to the test was not received within the allowable time period.
2100
ABRT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 3 times.
2500
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
XXYY
FAIL
On-board hardware or off-board signaling errors on the board.  XX 
indicates the on-board hardware error, and YY indicates the off-board 
errors on the as shown in 
1. Resolve any errors in error logs.
PASS
No service effecting errors or alarms were detected on the circuit pack.
0
NO 
BOARD
No board was detected by the test.
1. Check the Error Log for wrong board (Error Type 125) or no board 
(Error Type 131).  Resolve either of these issues, if applicable.
2. Check that the board is properly translated and inserted.  If so, check 
for hyperactivity (Error Type 1538).  If hyperactive, use reset board 
location
.
3. Run the test again.  If it fails, the NCE chip on board could be bad.  
Replace the board and retest.