Avaya 03-300430 User Manual

Page of 2574
ATM-SGRP (ATM Signaling Group)
Issue 1 June 2005
599
 
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 1: switch sent a message to the far-end switch or terminal adapter, and the far 
end did not respond in the allotted time.  Possible causes include link failure and congestion 
or outage at the far end.  The Aux Data field contains layer-3 protocol information used by 
internal counters.
If no other symptoms are present, no action is required.  If layer-3 communication is down:
a. Check for alarms and errors against link components
2. Check out other errors against ATM-SGRP, ATM-TRK, and other hardware components on 
the link.
There is no test to clear these errors.  The error counter is decremented by 1 every 15 
minutes.
Table 196: ATM-SGRP Signaling Group Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
0
Any
Any
test sig-group grp#
1 (
)
Any
None
18 (
)
MO busied out
257 (
Any
None
test sig-group grp#
769 (
Any
Primary Signaling Link 
Hardware check (#636)
test sig-group grp#
1281 
(
Any
Secondary Signaling Link 
Hardware check (#639)
test sig-group grp#
1793 
(
Any
Layer 2 Status test (#647)
WRN
OFF
test sig-group grp#
2305 
(
Any
Remote Layer 3 Query test  
(#637)
MIN
OFF
test sig-group grp#
3585 
(
Port 
number
None
3840 - 
3928 
(
Port 
number
None