ATM-WSP (ATM WAN Spare Processor)
Issue 1 June 2005
651
 
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 18: the ATM WSP has been busied out with busyout atm wsp. Check for 
other errors that require that the WSP be made maintenance busy.  Clear every related 
alarm.  After every related alarm is clear, or if there are no other alarms, release the ATM 
circuit pack using release atm wsp.
b. Error Type 257: the WSP has become active.  When a WSP takes over, the error becomes 
active and causes an alarm condition.  This error is not applicable for the main server.  To 
return the system to normal operation:
1. Run status atm wsp on the active WSP to verify that the main server or a 
higher-priority WSP that you want to be in control is “up.
2. If the main server or the higher-priority WSP is “up,” then run reset system 2.  The 
active WSP should relinquish control.
3. Wait a few minutes, and run list sys-link on the main server or higher-priority WSP 
to verify that the EAL and ACL system links are “up.”
c. Error Type 513: there is a down ATM WSP link status from this WSP to the main server or 
a higher-priority WSP.  If any of the links are considered down, this alarm is logged.  When 
every link probed by this WSP is “up,” the alarm should be cleared.
Remember that more than one link can be down.  To get a system-wide view of the status of 
the network run status atm wsp.
Aux Data Values are in the form of XYY where
X is the PNC: 0 = A-PNC, 1 = B-PNC
YY is the WSP number
Table 222: ATM-WSP Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
0
Any
Any
18 (
a
)
MO busied out
release atm wsp
257 (
b
)
Active WSP (#1401)
MAJ
OFF
reset system 2
513 (
c
)
WSP Link Status (#1400)
MIN
OFF
769 (
d
)
WSP #
WSP Priority Error
MIN
OFF
1025 (
e
)
WSP Error
WRN
OFF