Avaya 03-300430 User Manual

Page of 2574
Server Alarms
66 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
29
MAJ
“All fan failure” — Every fan is running at a critically low speed.
1. See if the alarmed condition is still present, either from the:
- Web interface, by selecting the View Temperature/Voltage 
diagnostic
- Linux command line, by entering environment
2. If not, manually clear the alarm, either from the:
- Web interface, by selecting Alarms and Notification, the 
appropriate alarm, and Clear
- Linux command line, by entering almclear -n #id
31
S8500B
MAJ
+1.5V under voltage. S8500B media server environment.
1. See if the alarmed condition is still present, either from the:
- Web interface, by selecting the View Temperature/Voltage 
diagnostic
- Linux command line, by entering environment
2. If not, manually clear the alarm, either from the:
- Web interface, by selecting Alarms and Notification, the 
appropriate alarm, and Clear
- Linux command line, by entering almclear -n #id
33
S8500B
MAJ
+1.5V over voltage. S8500B media server environment.\
1. See if the alarmed condition is still present, either from the:
- Web interface, by selecting the View Temperature/Voltage 
diagnostic
- Linux command line, by entering environment
2. If not, manually clear the alarm, either from the:
- Web interface, by selecting Alarms and Notification, the 
appropriate alarm, and Clear
- Linux command line, by entering almclear -n #id
Table 15: ENV Alarms in Media Server  (continued)
Event
ID
Alarm
Level
Alarm Text, Cause/Description, Recommendation
 7 of 8