Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
712 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
b. Error Type 2: violations of the ISDN-BRI signaling protocol; timers associated with certain 
layer-3 messages have expired before a required response was received.  In the following 
table, the aux data field indicates what timer has just expired. 
The switch sent a message to the endpoint that did not respond in the allotted time.  This 
can happen occasionally due to failure of the point-to-point signaling link or because of a 
problem in the BRI endpoint or ASAI adjunct or Avaya adjunct.  Execute test station 
extension
 sh and pay particular attention to the results of the BRI Layer 3 Query test 
(#629).  If this test fails, follow the repair procedure for Test #629.
c. Error Type 130: the circuit pack has been removed or has been insane for more than 11 
minutes.  To clear the error, replace or reinsert the circuit pack.
d. Error Type 257: the endpoint does not respond to the service state query message sent to 
the adjunct or the endpoint.  This error causes an alarm to be raised.  The alarm is retired 
when the switch receives a response to the service state query to the endpoint or the 
adjunct.
For BRI endpoints, the Aux Data field for this error contains “0.” When it occurs, execute 
test station extension sh and pay particular attention to the results of the BRI 
Layer 3 Query test (#629).  If this test fails, follow the repair procedure for Test #629.
Aux 
Data
Timer Type
2
First T303 (SETUP timer)
3
Second T303 (SETUP timer)
4
T305 (DISConnect timer)
5
First T308 (RELease timer)
6
Second T308 (RELease timer)
10
T316 (RESTart timer)
12
T309 (Layer-2 Failure timer)
16
TM100 (Management Information message 
Timer 1)
17
TM200 (Management Information message 
Timer 2)
102
TASAI (ASAI Routing timer)