Cycling Power Supplies
When a port carrier power supply problem is reported by hardware, the system can cycle the 
power supplies in that carrier.  When a carrier is cycled, the power supplies are turned off for 2 
seconds and then turned back on.  The system cannot cycle the power supplies on any of the 
following types carriers even if they are duplicated:
Expansion control carrier
Switch node carrier
Single-carrier cabinet
!
WARNING:
WARNING:
When port carrier power is cycled, all service dependent upon circuit packs in 
that carrier is disrupted.
Table 265: Carrier Port Power Supplies for
 
Multicarrier Cabinets
Code
System 
Power
Output (VDC)
Location
631DA
AC
+5
Left side
631DB
AC
-48/-5
Right side
644A
DC
+5
Left side
645B
DC
-48/-5
Right Side
TN755B
165
Slots 17 and 18
631WA/AR
AC
+5
Left side
631WB/BR
AC
-48
Right side
TN736
AC
-5
Used with 631
TN752
AC
165/-5
WA/WB or AR/AB
649A
AC
-48 at 10 Amps
+5 VDC and -5 VDC at 6 Amps
Right side on control and port 
carriers.  Left and right side on 