Avaya 03-300430 User Manual
CLAN-BD (Control LAN Circuit Pack)
Issue 1 June 2005
793
Notes:
a. Error Type 1: Circuit pack stopped functioning or is not physically present.
1. Verify that the circuit pack is present. If circuit pack is present, reset the circuit pack with
reset board location.
●
If the error persists, replace the circuit pack.
b. Error Type 18: The C-LAN circuit pack busied out.
c. Error Type 217: applies to 10 circuit packs:
1. Remove the circuit pack(s) against which the error is logged.
d. Error Type 257: Transient communication problem between switch and circuit pack; does
not affect service and can be ignored.
1. Ignore this error, unless the Control Channel Loop Test (#52) fails.
2. If Test #52 fails, replace the circuit pack.
Repetitive failures of the Control Channel Loop test indicate circuit pack hardware failure.
e. Error Type 513: Circuit pack detected and reported hardware failure.
1. Reset the circuit pack with reset board location.
Aux Data:
Aux Data:
f. Error Type 769: Logic error. By itself this error may be ignored, but it may result in other
error types being reported.
3862 (
)
Any
3865 (
Any
3866 (
Any
4352
External RAM error
4353
Internal RAM error
4355
ROM Checksum error
4356
Angel Message Corruption error
4357
Instruction set error
Table 269: CLAN-BD Error Log Entries (continued)
Error
Type
Type
Aux
Data
Data
Associated Test
Alarm
Level
Level
On/Off
Board
Board
Test to Clear Value
3 of 3