Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
928 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Circuit Packs:
8400x, 302B1 Terminals
TN754 (4-wire, mu-law)
Note:
Note:
Minimum usable vintage for 8410D and 8434D terminals - V11
TN413 (4-wire, A-law)
TN754B (4-wire, A-law/mu-law selectable)
TN2177 (2-wire, 16-port, A-law/mu-law selectable)
TN2181 (2-wire, 16-port, A-law/mu-law selectable)
TN2224 (2-wire, 24-port, A-law/mu-law selectable)
603A1/D1 Terminals
TN754 (4-wire, mu-law), 
TN413 (4-wire, A-law)
TN754B (4-wire, A-law/mu-law selectable)
S8300
 / 
G700
The MM712 Media Module supports 8410D and 8434D terminals (2-wire, 8-port, A-law/mu-law 
selectable).
Programmable Terminals
The following parameters are downloaded to programmable terminals.
Table 318: Parameters Downloadable to Programmable Terminals
Parameter
Scope
Terminal
International Flags (A-law/mu-law,
Display Mode, DLI Voltage level)
System level
84xx, 603x, 302B1
Primary Levels (Transmission & Sidetone)
System level
84xx, 603x, 302B1
Adjunct Levels (Transmission & Sidetone)
System level
84xx
Handset Expander Option
System level
84xx
Administrable Options
(Speakerphone & Mute Button)
Per-terminal
84xx 
Administrable Softkeys
Per-terminal, System level
8410D, 8434D