Bosch ICP-CC488 User Manual

Page of 118
ICP-CC488 | Installation Guide | 5.0  
System Functions 
EN | 23 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
Example 
To program RF wireless device number 3 whose 9-
digit ID number is 000094946, enter 
[1 2 3 4 0][AWAY][3][AWAY]  
[0 0 0 0 9 4 9 4 6][AWAY] 
To delete an RF wireless device: 
1.  Enter the Installer Code and press [0][AWAY]. 
Three beeps sound and the STAY and AWAY 
indicators flash. 
2.  Enter the RF device number (1 to 16) you want 
to delete and press [AWAY].  
Two beeps sound and the corresponding 
codepad indicators light to show the RF device 
number you selected. 
3.  Press [STAY] to delete the RF device. 
Two beeps sound and the STAY and AWAY 
indicators are extinguished. 
4.  Repeat Steps 1 to 3 to delete another RF wireless 
device. 
5.1.2 
Set the Number of Days until the First 
Test Report 
This function determines when the system sends the 
first Test Report (Contact ID Event Code 602). If you 
do not use this Installer Code function, the first Test 
Report is sent to the base station receiver after the 
repeat interval programmed in Location 428 (refer to 
Section 15.28 Test Reporting Time). If you want the 
system to send the first Test Report sooner than the 
repeat interval, use this function to set when the first 
Test Report is sent.  
To set the first Test Report: 
1.  Enter the Installer Code and press [1][AWAY]. 
Three beeps sound and the STAY and AWAY 
indicators flash. 
2.  Enter the number of days (1 to 15) until the first 
Test Report is sent and press [AWAY].   
Two beeps sound and the STAY and AWAY 
indicators are extinguished. The system returns 
to the disarmed state. 
 
Each time you enter Installer’s 
Programming Mode, the first Test Report 
time defaults back to the repeat interval 
set in Location 434. 
The number of days decrements by one at 
2400 hours as set in Locations 901 to 
904 (refer to Section 17.16 System 
Time
). 
Example 
If the repeat interval is set to 7 days, but you want 
the first Test Report to be sent in 2 days, enter: 
[1 2 3 4 1][AWAY][2][AWAY] 
5.1.3 
Change Domestic Phone Numbers 
When the system is set up for domestic dialing, this 
function allows the installer to view and program the 
telephone numbers the system calls if an alarm 
occurs. Refer to Section 9.0 Domestic Dialing on page 
42 for more information. 
To change domestic phone numbers: 
1.  Enter the Installer Code and press [2][AWAY]. 
Three beeps sound and the STAY and AWAY 
indicators flash.   
If no telephone numbers are programmed, they 
are displayed one digit at a time using the remote 
codepad indicators. Refer to Table 21 on page 24 
for the indicators and their meanings. 
If no telephone numbers are programmed, an 
additional two beeps sound after entering this 
mode. These two beeps normally sound after 
you enter the last digit of the last phone number. 
2.  Enter the first phone number. 
Each digit is displayed as you enter it. 
3.  If you are programming another phone number, 
press [STAY][4] to separate the end of one 
phone number and the beginning of the next. 
If you are not programming other numbers, go 
to Step 5
4.  Repeat Steps 2 and 3 to program another phone 
number. 
5.  Press [AWAY] to exit from this mode. 
 
Table 20:  Domestic Dialing Digits 
 
Digit 
Required 
Number to 
Program 
Digit 
Required 
Number to 
Program 
0 0  8  8 
1 1  9  9 
2 2   
 
3 3  * 
[STAY]1 
4 4  #  [STAY]2 
4 sec pause  
[STAY]3 
6 6  break 
[STAY]4 
7 7  15  [STAY]5 
Example 
If you want to program two separate telephone 
numbers (9672 1777 and 9672 1233), enter: 
[1 2 3 4 2][AWAY][9 6 7 2 1 7 7 7][STAY] 
[4 9 6 7 2 1 2 3 3][[AWAY] 
You can suspend domestic dialing at any time (for 
example, you are moving house and do not want the 
system to continue calling your work place or mobile 
phone). 
To disable domestic dialing: 
Enter the Installer Code and press [2][AWAY] 
[STAY][4][AWAY].