ICP-CC488 | Installation Guide | 19.0  
Partitioning 
EN | 85 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
19.3.1 Partitioning 
Options 
Location 
500 
Default 
First to open/last to close reporting 
Area 1 codepad connected to data terminal 
Reset sirens from any area allowed 
Master codepad to display AUX indicator when 
online 
1 – First To Open/Last To Close Reporting 
Select this option if only one Open/Close Report is 
required for a partitioned system. Instead of sending 
individual Open/Close reports for each area, a 
Closing Report is sent only after both areas are 
armed and an Opening Report is sent as soon as one 
area is disarmed. 
The reports are sent with the Subscriber ID Number 
allocated to the specific area. You must program 
Subscriber ID Numbers and Open/Close Reports for 
both areas. 
 
This option is applicable only when all 
User Codes have a priority level set with 
no open/close reports. If User Codes 
have priority levels set to Open/Close 
Reports, an Opening or Closing report is 
always sent when any area is disarmed or 
armed, regardless of whether the area 
was first to open or last to close. 
2 – Area 1 Codepad Connected to Data Terminal 
If this option is selected, the DATA terminal on the 
ICP-CC488 Control Panel is configured to send only 
status information that is relevant to Area 1. This 
allows you to connect an area addressable codepad 
(CP500A) set for Area 1 operation to the DATA 
terminal of the control panel instead of connecting 
the addressable codepad to an output.  
If this option is not selected, the CP5 Master 
Partitioned (CP500P) codepad must be used because 
the DATA terminal on the control panel displays 
information for both Area 1 and Area 2. 
An advantage to using this option is that you can 
configure a system into separate areas and preserve 
the maximum number of programmable outputs for 
other applications. 
4 – Reset Sirens from Any Area Allowed 
This option applies only to a partitioned control 
panel. If this option is selected, any valid User Code 
from Area 1 or Area 2 can reset the horn speaker, 
strobe, bell, or EDMSAT outputs while in alarm. 
This option does not allow a User Code allocated to 
one area to disarm another area. 
8 – Master Codepad To Display AUX Indicator 
When Online 
If this option is selected, the AUX indicator on the 
CP5 Master Partitioned (CP500P) codepad lights 
when the control panel seizes the telephone line to 
send a report. The AUX indicator is extinguished 
when the telephone line is released. 
19.3.2 Partitioning 
Options 
Location
501 
Default 
Lock Area 1 to Receiver 1 and Area 2 to Receiver 2 
User Code allowed to arm/disarm both areas at the 
same time 
4 Reserved 
8 Reserved 
1 – Lock Area 1 to Receiver 1 and Area 2 to 
Receiver 2 
If this option is selected, all reports for Area 1 are 
sent to Receiver 1 and all reports for Area 2 are sent 
to Receiver 2. 
If this option is not selected, you must manually 
program all reporting to be sent to Receiver 1 or 
Receiver 2 for both areas. 
2 – User Code Allowed To Arm/Disarm Both Areas 
at the Same Time 
If this option is selected, any user allocated to both 
areas can arm or disarm both areas at the same time 
without entering the code at each area codepad. 
Refer to Sections 5.2.1 and 5.3.1 for more information. 
If the user arms both areas at the same time and 
Option 1 is selected in Location 500 (refer to Section 
19.3.1 Partitioning Options 1 
on page 85), only a 
Closing Report for Area 2 is sent.  
If the user disarms both areas at the same time and 
Option 1 is selected in Location 500, only an 
Opening Report for Area 1 is sent. 
19.4 Zone 
Allocations 
You can allocate up to eight zones to each zone. The 
eight locations for each area are represented by the 
zone indicators on the remote area addressable 
codepad. You can map any zone to either area to 
appear as any zone on the remote area addressable 
codepad (that is, you can allocate a zone to both 
Area 1 and Area 2 to become a common zone, but 
each Area zone number cannot exceed 8). 
Zones programmed as common zones report to the 
base station receiver on group zero (Area 1 – Group 
1 and Area 2 – Group 2). Zones allocated to only one 
area report on the corresponding group number. 
Common zones, other than 24-Hour zone types, do 
not activate an alarm until both areas are armed in 
either AWAY Mode or STAY Mode 1.