Bosch ICP-CC404 User Manual

Page of 98
ICP-CC404 | Installation Guide | 2.0  
Programming 
 
 
14 Bosch 
Security 
Systems, 
Inc. | 12/08 | F01U089401-02
 
Table 6: 
Command 965 Defaults 
 
Location 
Description 
Default Value 
Setting 
032 
Handshake Tone for Receiver 1 
1  
(Handshake Tone) 
033 Transmission 
Format 
4  
(Domestic) 
034 to 039 
Subscriber ID Number 
0, 0, 0, 0, 0, 1 (1 
Beep) 
332 
Zone Status Reporting Options 
2 (Receiver 
only) 
333 and 334 
Open/Close Reports 
11, 12 (Open/Close 
Reports) 
335 
Open/Close Reporting Options 
2 (Receiver 
only) 
356 to 358 
System Status – Access Denied 
6, 7, 12 (Access 
Denied) 
359 
System Status Reporting Options 
2 (Receiver 
only) 
360 to 366 
Test Report Time 
0, 0, 0, 0, 7, 1, 0 (Test 
Reports) 
367 
Test Reporting Dialer Options 
1 (Receiver 
only) 
 
 
 
Example (Auto Step Mode Enabled) 
To enter the Primary Telephone Number 02 (pause) 
9672 1055 when Auto Step Mode is enabled:  
1.  Press [0 #].  
You are positioned at Location 000 (the Primary 
Telephone Number for Receiver 1). 
2.  To program the number, press: 
[10 * 2 * 13 * 9 * 6 * 7 *  2 * 1 * 10 * 5 * 5 * 0*] 
Example (Auto Step Mode Disabled) 
To enter the Primary Telephone Number 02 (pause) 
9672 1055 when Auto Step Mode is disabled: 
1.  Press [0 #].  
You are positioned at Location 000 (the Primary 
Telephone Number for Receiver 1). 
2.  To program the number, press: 
[10 * # 2 * # 13 * # 9 * # 6 * # 7 * # 2 * # 1 * # 
10 * # 5 * # 5 * # 0 *] 
2.4.10  Command 999 – Display the Panel Type or 
Software Version Number 
When using the remote codepad, this command 
shows the version of the control panel. Because 
different control panels use the same printed circuit 
board (PCB), it is difficult to determine the control 
panel the PCB is set to. 
To show the control panel type or software 
version number: 
1.  Enter the Installer Code (the default is 1234) and 
press [#] to enter Installer’s Programming Mode. 
Two beeps sound and the remote codepad shows 
the data programmed in Location 000. 
If you are using the remote codepad, the STAY 
and AWAY indicators flash to indicate you 
entered Installer’s Programming Mode.  
2.  Enter [9 9 9 #]. 
Two beeps sound. 
If you are using the remote codepad, the codepad 
displays a zone indicator corresponding to the 
control panel type. Refer to Table 7 for more 
information. 
 
Table 7: 
Control Panel Type 
 
Indicator Control 
Panel 
Type 
ICP-CC404 
8 ICP-CC408 
ICP-CC488 
 
3.  Press [#] to exit from this command and return to 
the Installer’s Programming Mode. 
4.  Enter [9 6 0 #] to exit from the Installer's 
Programming Mode. 
Two sound and the system returns to the 
disarmed state. 
If you are using the remote codepad, the STAY 
and AWAY indicators turn off to indicate the 
system is disarmed.