Bosch ICP-CC404 User Manual

Page of 98
ICP-CC404 | Installation Guide | 2.0   Programming 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089401-02 
15
 
2.5 
Disable Factory Defaults 
Program the Disable Factory Defaults feature in 
Location 900.  
The default value is 
0. 
This feature disables the DEFAULT button on the 
control panel printed circuit board (PCB) to prevent 
an operator from resetting the control panel to default 
values. This feature also prevents using a 
programming key when the system is disarmed.  
Program 0 into this location to enable the DEFAULT 
button and to allow updates to location data using the  
programming key. Program 15 to disable the 
DEFAULT button and to require the Installer Code 
to program the control panel.  
If the Installer Code is unknown, you must return the 
control panel to your Bosch Distributor for exchange. 
A nominal fee applies for this service. 
 
 
Using this feature is not recommended. 
 
If you need to disable the DEFAULT button, holding 
down the DEFAULT button on the PCB when 
programming this location prevents you from 
accidentally setting this option. 
To prevent manual resetting of the control panel 
to default values: 
1.  Enter the Installer Code (the default is 1234) and 
press [#] to enter Installer’s Programming Mode. 
Two beeps sound and the remote codepad shows 
the data programmed in Location 000. 
If you are using the remote codepad, the STAY 
and AWAY indicators flash to indicate you 
entered Installer’s Programming Mode. 
2.  Enter [9 0 0 #] to move to Location 900. 
3.  Press and hold the DEFAULT button.   
The DEFAULT button is located at the top of the 
PCB next to the PROGRAMMING KEY socket. 
4.  Enter [1 5 *] to program 15 into Location 900. 
5.  Release the button. 
6.  Enter [9 6 0 #] to exit from the Installer’s 
Programming Mode.   
Two beeps sound and the system returns to the 
disarmed state. If you are using a remote 
codepad, the STAY and AWAY indicators turn 
off to indicate the system is disarmed. 
If Location 900 is not programmed as 15, use one of 
these procedures to successfully reset the control 
panel to the factory default settings. 
To reset the control panel using the Installer 
Code: 
1.  Enter the Installer Code (the default is 1234) and 
press [#] to enter Installer’s Programming Mode. 
Two beeps sound. The STAY and AWAY 
indicators flashes to indicate you entered 
Installer’s Programming Mode. 
2.  Enter [9 6 5 #]. 
Two beeps sound after the control panel is 
successfully reset. 
3.  Enter [9 6 0 #].  
Two beeps sound. The STAY and AWAY 
indicators stop flashing and the system returns to 
the disarmed state. 
The control panel is now successfully reset to the 
factory settings. 
To reset the control panel using the default 
button: 
1.  Disconnect the AC MAINS supply and the 
backup battery from the control panel. 
Press and hold the DEFAULT button. The 
DEFAULT button is located at the top of the 
PCB next to the PROGRAMMING KEY socket. 
2.  Reconnect the AC MAINS supply to the control 
panel. 
3.  Wait 3 to 5 sec and release the button. 
4.  Enter [2 5 8 0 *] to disarm the system using the 
default Master Code. 
The control panel is successfully reset to the 
factory settings. 
 
If the option to restore the default control 
panel settings is disabled using Location 
900: 
•  The dialer seize relay (RL2) clicks four 
times. You must return the control 
panel to Bosch Security Systems, Inc. 
for exchange. If the Installer Code is 
unknown, a service fee is charged to 
unlock the control panel’s memory  
•  When programmed to disable the 
default control panel setting, you 
cannot use the command [961#] to 
retrieve the programming data. 
•  The use of this feature is not 
recommended.