Bosch ICP-CC404 User Manual

Page of 98
ICP-CC404 | Installation Guide | 3.0   Codepad Indicators 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089401-02 
17
 
Table 12: 
FAULT Indicator 
 
Indicator Definition 
On 
A system fault must be corrected 
Off 
The system is normal (no faults) 
Flashing 
A system fault must be acknowledged 
 
Audible Indicators 
The codepad provides these audible indications: 
 
Table 13: 
Audible Indicators 
 
Audible Indicator 
Definition 
One short beep 
A button was pressed on the 
codepad, or Exit Time ended when 
arming in STAY Mode 1 or STAY 
Mode 2 
Two short beeps 
The system accepted the code 
Three short beeps 
The system executed the requested 
function 
One long beep 
Exit Time ended when arming in 
AWAY Mode, or the requested 
operation was denied or aborted 
One short beep 
every second 
Walk Test Mode is currently active, 
or warning before automatic arming 
takes place 
One short beep 
every 2 sec 
Telephone Monitor Mode is active. 
One short beep 
every minute 
There is a system fault to 
acknowledge 
 
3.2 
ICP-CP508LW Eight Zone LCD 
Codepad 
Figure 2: 
ICP-CP508LW Eight Zone LCD 
Codepad 
 
 
The codepad is the communications interface 
between you and the alarm system. The codepad 
allows you to issue commands and offers visual and 
audible indications to guide you through general 
operation. 
The codepad uses a number of indicators: eight zone 
indicators show the condition of each zone and seven 
other indicators show general status. These indicators 
are described in this section. 
Zone Indicators 
1 2 3 …
The zone indicators (1 to 8) show the 
status of the zones as listed in Table 8 on 
page 16. 
AWAY Indicator 
 
The AWAY indicator lights when the 
system is armed in AWAY Mode. The 
ON indicator also lights when the 
system is armed in AWAY Mode (refer 
to Table 10 on page 16).  
The AWAY indicator flashes with the STAY 
indicator when you are in Installer’s Programming 
Mode or you are using a Master Code function. 
Refer to Section 4.1 Arming the System in AWAY Mode  
on page 18 for more information. 
STAY Indicator 
 
The STAY indicator lights when the 
system is armed in STAY Mode 1 or 
STAY Mode 2 (refer to Table 9 on 
page 16). 
The STAY indicator also flashes with the AWAY 
indicator when you are in Installer’s Programming 
Mode or you are using a Master Code function.  
The ON indicator also lights when the system is 
armed in STAY Mode 1 or STAY Mode 2.  
For more information, refer to: 
•  Section 4.3 on page 19 to arm the system in 
STAY Mode 1.  
•  Section 14.3.4 on page 57 to set zones to 
automatically isolate in STAY Mode 1.  
•  Section 4.5 on page 20 to arm the system in 
STAY Mode 2.   
•  Section 6.1.4 on page 30 to use the Installer Code 
to set zones to automatically isolate in STAY 
Mode 2. 
•  Section 6.2.5 on page 35 to use the Master Code 
to set zones to automatically isolate in STAY 
Mode 2. 
System Disarmed 
 
This indicator lights with the OFF 
indicator when the system is disarmed. 
MAINS Indicator 
The MAINS indicator shows when the 
systems AC MAINS supply is normal or 
failed (refer to Table 11 on page 16). 
When programming in Installer’s Programming 
Mode or using a Master Code function, the MAINS 
indicator lights to indicate a location value from 10 to 
15. The MAINS indicator represents the 10 digit, 
which is added to the value of the lit zone indicator 
(for example, if the value programmed in a location is 
12, the MAINS and Zone 2 indicators light).