ICP-CC404 | Installation Guide | 1.0  
Introduction 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089401-02
 
When programming the telephone numbers for 
Receiver 1 and Receiver 2, you must program a 0 
as a 10. Programming a 0 in the telephone 
number indicates the end of the dialing sequence. 
Unless otherwise stated, program a 0 as a 0 in all 
locations other than the telephone numbers for 
Receiver 1 and Receiver 2, and the Call Back 
Telephone Number. 
6.  If required, set the Test Report time. Program 
any other required changes. Otherwise, factory 
default settings are used. Refer to Section 15.21 
Test Reporting Time
 on page 63 for more 
information. 
7.  Enter command [9 6 0] and press [AWAY] to exit 
from the Installer’s Programming Mode.   
Two beeps sound and the STAY and AWAY 
indicators turn off. The system returns to the 
disarmed state and is ready for use. Refer to 
Section 2.4 Installer’s Programming Commands on 
page 10 for more information. 
8.  Use the Master Code to set the date and time. 
Refer to Section 1.2.1 Setting the Date and Time for 
more information. 
1.2.1 
Setting the Date and Time 
1.  Enter your Master Code and press [6][AWAY]. 
Three beeps sound and the STAY and AWAY 
indicators flash. 
2.  Enter the day, month, year, hour, and minute in 
DD, MM, YY, HH, MM format (where DD is the 
day of the month, MM is the month of the year, 
YY is the year, HH is the hour of the day, and 
MM minute of the day) and press [AWAY]. 
Use 24:00 hour format when programming the 
hour of the day. 
Two beeps sound and the STAY and AWAY 
indicators turn off. If a long beep sounds, there 
was an error when you entered the date and time. 
Example 
To set the date and time for the 1st January 2006 at 
10:30 PM, enter: 
[2 5 8 0 6][AWAY][0 1 0 1 0 6 2 2 3 0][AWAY] 
1.2.2 Zone 
Defaults 
The default zone settings for the control panel are 
listed in Table 1. You can program Zones 1 to 4 to 
any of the zone types. Refer to Table 2 for the zone 
types you can select. 
 
Table 1: 
Zone Defaults 
 
 
Zone Zone 
Type 
Zone 
 Zone 
Type 
Delay-1 
24-Hour Burglary 
2 Handover 
24-Hour 
Burglary 
Handover 
24-Hour Fire 
4 Instant 
24-Hour 
Tamper 
 
1.2.3 Zone 
Types 
There are thirteen zone types to choose from when 
programming zones for the ICP-CC404 Control 
Panel. Refer to Section 14.3 Zone Programming on 
page 54 for more information. 
 
Table 2: 
Zone Types 
 
 
Type Description 
Type Description 
Instant 
24-Hour Holdup 
1 Handover 
9 24-Hour 
Tamper 
Delay-1 
10 
Reserved 
3 Delay-2 
11 
Keyswitch 
Reserved 
12 
24-Hour Burglary 
5 Reserved 
13 
24-Hour 
Fire 
24-Hour Medical 
14 
Chime only 
7 24-Hour 
Panic 
15 
Zone 
not 
used