ICP-CC404 | Installation Guide | 2.0   Programming 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089401-02 
9
 
2.0   Programming 
The control panel programming options are stored in 
a non-volatile EPROM. This memory holds all 
configuration and user-specific data even after a total 
power loss.  
Because the data retention time is up to ten years 
without power, no reprogramming is required after 
powering down the control panel. 
You can change data as many times as necessary 
without any additional specialized equipment. The 
memory is organized in locations, each of which 
holds the data for a specific function. 
 
 
15 is the maximum value that you can 
program into any location. 
 
In general, the entire programming sequence consists 
of selecting the required location, and then entering 
or changing the current data. Repeat this procedure 
until you program all the required data. The factory 
default settings are selected for reporting to the 
monitoring station in Contact ID format. 
The Installer Code provides access only to the 
Installer’s Programming Mode and does not allow 
you to arm and disarm the system. You cannot enter 
Installer’s Programming Mode when the system is 
armed, or at any time during siren run time. 
You can program the ICP-CC404 Control Panel 
using any of these three devices: 
•  Remote codepad 
•  CC816 Alarm Link Upload/Download Software 
2.1 
Programming with the Remote 
Codepad 
To program the control panel using the remote 
codepad, the system must be disarmed with no alarm 
memory present.   
To access Installer’s Programming Mode: 
Enter the four-digit Installer Code (the factory default 
is 1234) and press [AWAY].  
Two beeps sound and both the AWAY and the 
STAY
 
indicators flash simultaneously to indicate that 
you entered Installer’s Programming Mode.   
When you enter Installer’s Programming Mode, you 
are automatically positioned at Location 000, the first 
digit of the Primary Telephone Number for Receiver 
1. The codepad indicators display the current data 
stored in this location. 
Table 3: 
Codepad Indicators 
 
Data  
Zone Indicators 
 
Value 
1 2 3 4 5 6 7 8 MAINS 
 
 
 
 
 
 
 
 
 
X
 
 
 
 
 
 
 
 
 
X
 
 
 
 
 
 
 
 
 
X
 
 
 
 
 
 
 
 
 
X
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
X
 
 
 
 
 
 
 
10 
 
 
 
 
 
 
 
 
11 
X
 
 
 
 
 
 
 
12 
 
X
 
 
 
 
 
 
13 
 
 
X
 
 
 
 
 
14 
 
 
 
X
 
 
 
 
15 
 
 
 
 
 
 
 
 
To move to a different programming location: 
Enter the location number and press [AWAY]. 
For example, press [3 4][AWAY] to automatically 
step you to the beginning of the Subscriber ID 
Number for Receiver 1. The data stored in the new 
location appears. 
To move to the next location: 
Press [AWAY].   
For example, if you are currently positioned at 
Location 034, press [AWAY] to step to Location 035. 
To move to the previous location: 
Press [STAY]. 
For example, if you are positioned at Location 035, 
press [STAY] to step back to Location 034. 
To change data in the current location: 
Enter the new value (0 to 15) and press [STAY].   
The data is stored and you remain positioned at the 
same location. The codepad indicators show the new 
value (for example, if you enter [1 4] and press 
[STAY], the Zone 4 and MAINS indicators light). 
To exit from the Installer’s Programming Mode: 
Enter command [9 6 0] and press [AWAY].  
Two beeps sound and the STAY and AWAY 
indicators turn off. The system returns to the 
disarmed state and is now ready for use.   