Bosch FW5.50 User Manual

Page of 94
Camera Browser Interface
Network | en
81
Bosch Security Systems
Software manual
AM18-Q0611 | v5.50 | 2012.03
The camera uses the TLS 1.0 protocol. Ensure that the browser 
has been configured to support this protocol. Also ensure that 
Java application support is activated (in the Java Plug-in 
Control Panel of the Windows Control Panel).
To limit connections to SSL encryption, set the Off option in 
the HTTP browser port, the RCP+ port, and Telnet support. This 
deactivates all unencrypted connections allowing connections 
on the HTTPS port only.
Configure and activate encryption for media data (video, audio, 
metadata) on the Encryption page.
14.1.8
RCP+ port 1756
Activating RCP+ port 1756 allows unencrypted connections on 
this port. To allow only encrypted connections, set the Off 
option to deactivate the port.
14.1.9
Telnet support
Activating Telenet support allows unencrypted connections on 
this port. To allow only encrypted connections, set the Off 
option to deactivate telnet support, making telnet connections 
impossible.
14.1.10
Interface mode ETH
If necessary, select the Ethernet link type for interface ETH
Depending on the device connected, it may be necessary to 
select a special operation type.
14.1.11
Network MSS [Byte]
Set the maximum segment size for the IP packet's user data 
here. This gives the option to adjust the size of the data packets 
to the network environment and to optimize data transmission. 
In UDP mode, comply with the MTU value set below.
14.1.12
iSCSI MSS [Byte]
Specify a higher MSS value for a connection to the iSCSI 
system than for the other data traffic via the network. The 
potential value depends on the network structure. A higher 
value is only useful if the iSCSI system is located in the same 
subnet as the camera.