D623 Series/D625 Series | User's Guide |  
 
 
14 
Bosch Security Systems | 9/04 | 46841E 
 
Table 5:  Silencing Exit Tone 
 
Arming With 
To Silence Exit Tone 
All On 
Press and hold [ALL ON] 
OR 
Press [CMD], then press and hold [1]. 
Part On 
Press and hold [PART ON] 
OR 
Press [CMD], then press and hold [2]. 
Part 2 On 
Press [CMD], then press and hold [3]. 
 
 
Silencing the Exit Delay Tone doubles the 
Exit Delay period. 
 
3.
 
Enter your passcode if necessary. The keypad 
display shows the following for turning the system 
All On: 
To bypass points
press Bypass.
120 seconds to
All On.
For no delay
Press No Delay.
 
If all points are normal, the display shows the 
following for Part On or Part 2 On. If the system is 
turned Part 2 On, the second line of the display 
shows Part 2 On: 
To bypass points
press Bypass.
120 seconds to
Part On.
For no delay
Press No Delay.
 
4.
 
To turn the system on (All On, Part On, or Part 2 
On) with no delay, press [NO DELAY]. See Turn 
the System On with No Delay on page 14 for 
more information. 
 
Turn the System On with Points 
Faulted (Force Arm) 
 
 
Force-arming is not permitted for UL 
applications. 
 

 
I can perform this command. 

 
I cannot perform this command. 
1.
 
Press [ALL ON] or [PART ON] to turn the system 
All On or Part On. 
2.
 
The keypad displays the faulted points as follows: 
Pt5 faulted,
Point Text
To Bypass Pt5
Press 5 + *
 
Then the system identifies the faulted point (in this 
example Point 5), followed by instructions for 
bypassing the point. 
3.
 
To force arm the system All On or Part On with 
normal Exit Delay and exit tone, press [ALL ON] 
or [PART ON] again. Enter your passcode when 
prompted. The following scrolls across the display: 
Forced on!
60 seconds to
All On.
1 points are
forced on.
 
 
 
The display above uses an Exit Delay time 
of 60 sec. and only one point is force-
armed. Exit Delay time and the number of 
points forced on may vary. 
 
4.
 
To force arm the system All On or Part On with 
Exit Delay doubled and no exit tone, press and 
hold [ALL ON] or [PART ON] until the “point 
faulted” message appears (see figure in Step 2). 
Then press [ALL ON] or [PART ON] again. Enter 
your passcode if prompted. The system then scrolls 
the 
Forced on!
 message and the doubled Exit 
Delay Time countdown. The exit tone is silenced. 
The system ‘forces’ the faulted points on. As long 
as they remain faulted they do not provide 
protection. If the faulted points return to normal 
before the system is turned off, they provide 
protection and are capable of starting alarm events. 
If a point becomes faulted after the exit delay 
begins, the keypad displays the faulted point. If the 
point remains faulted at the end of exit delay, it 
starts an alarm event.