Bosch D625 User Manual

Page of 48
D623 Series/D625 Series | User's Guide | Basic Pager Reports 
 
 
32 
Bosch Security Systems | 9/04 | 46841E 
 
Table 7:  Character Code Information 
 
Display Description 
A# 
Area number 
Pt## Point 
number 
Dv### 
Device number 
Ln## 
Phone line number 
Mn# 
Minutes until Auto Arm Sked 
Cd## 
User Code number 
Op## 
Output number 
Ks## Keyswitch 
number 
U## 
User number 
## 
Communication status for Routing Destinations 
1 and 2 
- (dash) 
Destination disabled 
A Aborted 
Deleted from pending buffer by control panel 
reset 
F Faulted 
Local 
P Pending 
Sent 
 
 
Basic Pager Reports 
A pager’s display can show up to four fields of 
information in the following order: 
 
Figure 7:  Pager Display format 
(Account Number) - (Event Number) - (Area Number) - (Point/User Number)
 
 
 
Account Number: 4-digit account number. If the 
account number is greater than four digits, the first 
four digits are sent. 
 
Event Number: Panel event numbers. See Panel 
Event Descriptions on page 43  for information on 
control panel events. 
 
Area Number: Area number the faulted point is 
assigned to.  
 
Point/User Number: Point number assigned to 
the faulted point. This field can also show a User 
ID number. 
Depending on its configuration, your pager can display 
any combination of the four fields shown in the order 
above with or without field separators. For example:  
 
Account Number: 1234 
 
Event Number: 08 
 
Area Number: 02 
 
Point Faulted: 21 
A pager display configured to show all four fields with 
separators using the sample information from above 
would look like: 
1234-08-02-21 
A pager display configured to show all four fields 
without separators using the sample information from 
above would look like: 
1234080221. 
Contact your security company to modify pager 
display configuration. 
 
User IDs 1 to 32 are reserved for system user. 
 
User ID 252 is reserved for sked operation. 
 
User ID 253 is reserved for remote telephone 
communication. 
 
User ID 254 is reserved for remote programming 
communication. 
 
User ID 255 is reserved for keyswitch operation.