4.  
Codepad Indicators 
Figure 1:  CP5 Eight Zone LED Codepad 
 
 
Figure 2:  CP5 Eight Zone LCD Codepad 
The codepad is the communications interface 
between you and your alarm system. Use the 
codepad to issue commands. The codepad offers 
both visual and audible indications that guide you 
through the general operation. 
The codepad incorporates numerous indicators. 
There are zone indicators that show the condition of 
each zone and four other indicators for general 
status. The following pages outline a list of situations 
and the relevant indicators that are seen. 
4.1 Zone 
Indicators 
1 2 3 ….
The zone indicators (1 to 8) display 
the status of the zones. Table 2 lists the 
various situations that the indicators 
display (such as, Zone Sealed/Zone 
Unsealed). 
Table 2: 
Zone Indicator 
 
Zone Indicator 
Definition 
On 
Zone is unsealed. 
Off 
Zone is sealed. 
Flashing Fast 
(0.25 seconds on/ 
0.25 seconds off) 
Zone is in alarm condition. 
Flashing Slow 
(1 second on/ 
 1 second off) 
Zone is manually isolated or 
selected to be isolated. 
4.2 AWAY 
Indicator 
 
The AWAY indicator displays the 
system is armed in AWAY Mode. The 
AWAY indicator also flashes in unison 
with the STAY indicator when 
programming various options 
throughout the Operators Guide
See Section 5.1 Arming in AWAY Mode 
for information on the different 
methods of arming the system in 
AWAY Mode. 
Table 3: 
AWAY Indicator 
 
AWAY 
Indicator 
Definition 
On 
System is armed in AWAY Mode. 
Off 
System is not armed in AWAY Mode. 
4.3 STAY 
Indicator 
 
The STAY indicator displays the system 
is armed in STAY Mode 1 or STAY 
Mode 2. The STAY indicator also flashes 
in unison with the AWAY indicator 
when programming various options 
throughout the Operators Guide
See Section 5.2 Arming in STAY Mode 1 for 
different methods of arming in STAY 
Mode 1. See Section 5.3 Arming in STAY 
Mode 2 
to arm in STAY Mode 2. 
Table 4: 
STAY Indicator 
 
STAY 
Indicator 
Definition 
On 
System is armed in STAY Mode 1 or 
STAY Mode 2. 
Off 
System is not armed in STAY Mode 1 
or STAY Mode 2. 
Flashing twice 
a second 
Zone Isolating Mode or setting STAY 
Mode 2 zones. 
Flashing once 
every 3 
seconds 
Day alarm status – day alarm turned 
on. 
4.4 System 
Disarmed 
 
This indicator displays with the 
 