CC408 | Operators Guide | 5.   Arming the System 
EN | 8 
 
Bosch Security Systems | 5/04 | 920050O.OG.112 
Forced Arming 
The feature of arming the system when a zone is not 
sealed is known as forced arming. If the system does 
not arm and a long beep is heard, forced arming is 
not permitted. If this is the case, ensure that all zones 
are sealed or manually isolated before arming the 
system. 
5.1 
Arming in AWAY Mode 
When you leave your premises and require all zones 
to be in a ready state to detect intrusion, you arm the 
system in AWAY Mode. When returning to your 
premises, disarm your system (see Section 6. Disarming 
the System) 
so you do not sound a false alarm. 
There are two different methods for arming the 
system in AWAY Mode. Method one is standard and 
always operates. Method two is optional and may be 
disabled by your installer if you do not want to use 
single button arming. 
Arming in AWAY Mode, Method 1 
Enter your user code followed by the [#] key (for 
example, [2 5 8 0 #]). Two beeps sound and the 
AWAY indicator displays. Exit time starts counting. 
Arming in AWAY Mode, Method 2 
Hold down the [#] key until two beeps sound. 
The AWAY indicator displays and exit time starts 
counting. 
5.2 
Arming in STAY Mode 1 
STAY Mode 1 is only used when the perimeter and 
unused areas of the premises must be armed to 
detect if an intruder is entering the premises. At the 
same time it allows you to move freely within an area 
that is automatically isolated. 
 
Only your security company can program 
zones automatically isolated in STAY  
Mode 1. 
There are two different methods for arming the 
system in STAY Mode 1. Method one is standard 
and always operates. Method two is optional and 
may be disabled by your installer if you do not want 
to use single button arming. 
Entry Guard Timer for STAY Mode 1 
When arming the system in STAY Mode 1, an 
optional entry timer called Entry Guard Timer For 
STAY Mode 1 is available. Use this entry timer to 
delay the sirens if a zone is not automatically isolated 
and triggers an alarm condition. Entry Guard Timer 
For STAY Mode 1 is the delay time used for all 
zones except 24-hour zones when the system is 
armed in STAY Mode 1 or STAY Mode 2. 
If the Entry Guard Timer For STAY Mode 1 is 
programmed and a zone not automatically isolated is 
triggered, the codepad beeps twice per second until 
the entry timer expires or the system disarms. If the 
alarm condition is not reset by entering your user 
code followed by the [#] key (for example, 
[2 5 8 0 #]) before the entry timer expires, the sirens 
activate into alarm. Only your installer can program 
this feature. 
Arming in STAY Mode 1, Method 1 
Enter your user code followed by the [*] key (for 
example, [2 5 8 0 *]). Two beeps sound and the 
STAY indicator displays. Exit time starts counting. 
Any zones programmed to be automatically isolated 
in STAY Mode 1 flash until exit time expires. At the 
end of exit time, all zones selected to be 
automatically isolated turn off and the codepad gives 
one short beep. 
Arming in STAY Mode 1, Method 2 
Hold down the [*] button until two beeps are heard. 
The STAY indicator displays and exit time starts 
counting. 
Any zones programmed to be automatically isolated 
in STAY Mode 1 flash until exit time expires. At the 
end of exit time, the zone indicators turn off and the 
codepad emits one short beep. 
5.3 
Arming in STAY Mode 2 
STAY Mode 2 is only used when the perimeter and 
unused areas of the premises must be armed to 
detect an intruder from entering the premises while 
you move freely within an area that is automatically 
isolated. Any Master Code user can program zones 
to be automatically isolated in STAY Mode 2. 
Entry Guard Timer For STAY Mode 2 
When arming the system in STAY Mode 2, an 
optional entry timer called Entry Guard Timer For 
STAY Mode 2 is available. Use this entry timer to 
delay the sirens if a zone is not automatically isolated 
and triggered into alarm condition. Entry Guard 
Timer for STAY Mode 2 is the delay time used for 
all zones except 24-hour zones when the system is 
armed in STAY Mode 1 or STAY Mode 2. 
If the Entry Guard Timer For STAY Mode 2 is 
programmed and a zone not automatically isolated 
triggers, the codepad beeps twice a second until the 
entry timer expires or the system disarms. If the 
alarm condition is not reset by entering your user 
code followed by the [#] button (for example, 
[2 5 8 0 #]) before the entry timer expires, the sirens 
activate into alarm. Only your installer can program 
this option.