Gas-Fired Products 100 User Manual

Page of 53
Form #43343530 
 
 
July 08 
–5– 
 
5.0) SPECIFICATIONS 
 
 
* MOUNT HEATERS AS HIGH AS POSSIBLE. Minimums are shown as a guideline for human comfort and uniform 
energy distribution for complete building heating applications. Consult your Space-Ray representative for the 
particulars of your installation requirements. 
 
Type 
Gas: 
Gas-Pipe 
Connection:
 
 
Tube 
Diameter: 
Flue 
Connection: 
1
 
Fresh Air 
Connection: 
1
 
Electrical 
Supply: 
Current 
Rating: 
Natural 
or Propane 
½” MPT 
(Male) 
4” 
4” Round 
4” Round 
120 Volt, 
60Hz, 1 Phase 
1.74 Amp 
 
1)  See Section 16 for vent sizes when multiple heaters are connected into a common vent. 
 
Module Electrical Rating: 
 
Ignition System (direct spark): 
 
Input Power-Control: 18-30 VAC  50/60 Hz (class 2 
transformer) 
Input Power-Line: 120 VAC (L1, IND contacts only) 
Gas Valve Rating: 2.0 A @ 24 VAC (max.) 
Combustion Blower Rating: 3.0 FLA @ 120 VAC 
                                               1/4 H.P. Motor 
Flame Sensitivity: 0.7 microamps minimum 
15 second trial for ignition period 
15 second pre-purge period 
60 second inter-purge period 
30 second post-purge period 
3 tries for ignition (separate flame sensor). 
 
6.0) PACKING 
LIST 
 
A)  PTS/PTU Burner Package 
   
QTY 
Burner Box Assembly   (Refer to the following chart for Package Part Numbers)  
4”ID x 4”Lg Flue Adapter Collar   (#30504500) ...................................................................1 
Fastener Kit – Burner Box Attachment/Flue Adapter Collar  (#42907040)....................1 
            containing:     #10 x 1/2” Self-Drilling Screws   (#02189020)..............................2 
 
            ¼ - 20 Locknuts   (#02167010) ..............................................................3 
 
Tube Flange Gasket   (#42921000).......................................................................................1 
 
Turbulator 24” Long (#44152240)  *See chart above for required quantities. 
 
 
Installation & Operation Instructions   (#43343530)..........................................................1 
 Turnbuckle   (#30545040) ......................................................................................................1 
 
Gas connector 5/8” OD x 36”  (#30302360) .......................................................................1 
 
Orifice Size 
Minimum * 
Mounting Height 
Model No. 
 
High 
Btu/hr 
Input 
 
Low 
Btu/hr 
Input 
Combustion 
Air Plate 
Part # 
Natural Gas 
Propane Gas 
Horizonta
45º Angle 
Turbulator
Qty. 
PTS/PTU 40/25 
40,000  25,000 
#44140061 
#32 
(0.116) 
#49 
(0.073) 
10 ft. 
9 ft. 
PTS/PTU 50/30 
50,000  30,000 
#44140064  3.5mm 
(0.138) 
46 
(0.081) 
11 ft. 
10 ft. 
PTS/PTU 75/50 
75,000  50,000 
#44140063 
#21 
(0.159) 
2.5mm 
(0.098) 
13 ft. 
12 ft. 
PTS/PTU 100/65 
100,000  65,000 
#44140062 
#12 
(0..189)) 
#32 
(0.116) 
14 ft. 
13 ft. 
PTS/PTU 125/80 
125,000  80,000 
#44140066 
#4 
(0..209) 
#30 
(0.129) 
14 ft. 
13 ft. 
PTS/PTU 150/100  150,000  100,000  #44140067 
“A” 
(0.234) 
#27 
(0.144) 
15 ft. 
14 ft. 
PTS/PTU 175/110  175,000  110,000  #44140067 
“E” 
(0.250) 
#23 
(0.154) 
16 ft. 
15 ft. 
PTS/PTU 
200/125 200,000 125,000 #44140068 6.9mm 
(0.272) 
4.1mm 
(0.161) 
18 ft. 
16 ft.