  Fault 
Codes 
     
 
 
 
 
 
 
 
 
 
 
 
 
 
If there is a malfunction the appliance may shut down 
as a safety precaution and display a fault code to 
assist in diagnosing the problem.  The fault code will 
flash in the display on the control panel.  When 
making a service call, this code will assist with 
diagnosing the fault.  
You may be able to clear the fault code by turning the 
heater off and then on again.  If the fault code remains 
or returns on the next operation, contact Rinnai or 
your nearest service agent and arrange for a service 
call. 
Rinnai Corporation RHFE-263FA
13
CODE DISPLAYED
FAULT
REMEDY
Ignition failure
Flame failure
Overheat
Room overheat
Room Temperature
Sensor faulty
Overheat Temperature
Sensor faulty
Sparker failure
Combustion fan failure
Faulty ON/OFF switch
Faulty solenoids 
Faulty Flame Rod
Communication Error
Check gas is turned ON.
Service call if repeated.
Check gas is turned ON.
Service call if repeated.
Clean filter
Service call if repeated. [1]
Service call.
Service call.
Service call.
Service call.
Service call.
Service call.
Service call.
Turn heater OFF, 
then ON again.
Lower room temperature
to less than 104
°F(40°C).
Flue block
Check around flue terminal [2]
11
12
14
16
31
32
33
34
53
61
70
71
72
73
49
99
Sensor breakdown
Service Call.
[1] Remove any obstructions.  The flue needs to be kept clear to expel exhaust gases.  If the appliance fails to 
operate contact a qualified service agency. 
[2] If the fusible link needs replacement, it must be done by a qualified service agency.  In addition, the cause of 
the overheat needs to be determined.  The fusible link is a one use safety device that breaks to shut off the
appliance.