Thermo Products OHFA199DV5B User Manual

Page of 78
 
 32 
 
Cooling Speed Set-ups   
OH8FA119DV5 
 
 
 
 
 
 
 
Furnace Motor Current 
 
 
 
 
 
 
 
Draw (Amps/Watts) vs. 
 
 
 
 
 
 
 
External Static Pressure (in W.C.) 
 
  
  
Air Flow 
 
 
 
 
 
 
Fan 
Control 
SW 1 
Switch 
Settings 
Clg. 
Tonnage 
Cool 
 
   Continuous 
 
 
 
 
 
Dehum 
 
 
 
 
 
.02 
 
 
 
 
 
.05 
 
6-OFF      
5-OFF       
4-OFF 
800 
500 
 
557 
 
1.0/89 
 
1.8/161 
 
6-OFF       
5-OFF       
4-ON 
2.5 
1018 
509 
 
703 
 
 
1.4/121 
 
2.1/192 
 
6-OFF        
5-ON       
4-OFF 
1212 
606 
 
848 
 
1.8/159 
 
2.6/231 
 
6-OFF        
5-ON       
4-ON 
3.5 
1406 
703 
 
994 
 
2.3/203 
 
3.1/290 
Factory 
SW1 
Switch 
Settings 
6-ON        
5-OFF       
4-OFF 
1624 
800 
 
1139 
 
 
3.0/278 
 
4.0/378 
 
6-ON 
5-OFF 
4-ON 
4.5 
1818 
897 
 
1285 
 
3.8/353 
 
5.0/475 
 
6-ON 
5-ON 
4-OFF 
2012 
994 
 
1406 
 
4.8/456 
 
6.0/582 
 
6-ON 
5-ON 
4-ON 
5.5 
2230 
1115 
 
1551 
 
6.1/593 
 
7.4/729 
 
NOTE:  All information is approximate. Results will vary by installation. 
 
Figure 18-3A:  Cooling blower motor speed chart