Thermo Products OHFA199DV5B 用户手册
32
Cooling Speed Set-ups
OH8FA119DV5
Furnace Motor Current
Draw (Amps/Watts) vs.
External Static Pressure (in W.C.)
Air Flow
Fan
Control
SW 1
Switch
Settings
Control
SW 1
Switch
Settings
Clg.
Tonnage
Cool
Continuous
Dehum
.02
.05
6-OFF
5-OFF
4-OFF
5-OFF
4-OFF
2
800
500
557
1.0/89
1.8/161
6-OFF
5-OFF
4-ON
5-OFF
4-ON
2.5
1018
509
703
1.4/121
2.1/192
6-OFF
5-ON
4-OFF
5-ON
4-OFF
3
1212
606
848
1.8/159
2.6/231
6-OFF
5-ON
4-ON
5-ON
4-ON
3.5
1406
703
994
2.3/203
3.1/290
Factory
SW1
Switch
Settings
SW1
Switch
Settings
6-ON
5-OFF
4-OFF
5-OFF
4-OFF
4
1624
800
1139
3.0/278
4.0/378
6-ON
5-OFF
4-ON
5-OFF
4-ON
4.5
1818
897
1285
3.8/353
5.0/475
6-ON
5-ON
4-OFF
5-ON
4-OFF
5
2012
994
1406
4.8/456
6.0/582
6-ON
5-ON
4-ON
5-ON
4-ON
5.5
2230
1115
1551
6.1/593
7.4/729
NOTE: All information is approximate. Results will vary by installation.
Figure 18-3A: Cooling blower motor speed chart