Thermo Products OH8FA119D60B User Manual

Page of 78
 
 39 
 
 
ECM & PSC TROUBLE SHOOTING 
 
DIAGNOSTIC FEATURES 
 
The control board is equipped with 4 green Input Status LEDs and 1 red Board Status LED. These are 
intended to provide a quick view into furnace performance without requiring a voltmeter.  
 
 
 
The green Input Status LEDs are driven by the “Y”, “W”, “G”, and “DEHUM” inputs and are located 
directly below those inputs. They will light to indicate the presence of these signals. 
 
 
The red Board Status LED has two functions: 
 
It will light when the board recognizes a valid input signal and will stay lit until all valid signals are 
removed. This is intended to show that the board is functioning and able to respond to input signals. 
 
 
 
It will flash rapidly while 120VAC is missing from the LIMIT switch. This is intended to give a quick 
visual indication of the High Limit switch.