Sony 900 User Manual

Page of 203
7
Chapter 7 Location and Function of Parts and Controls
89
HDC-900/950/930 Series Product Information Manual
750 Master Setup Unit or RCP-700 series 
Remote Control Panel. Either a recall-type 
monitor, or the 1730HD/1735HD Waveform 
Monitor, may be connected. When using a 
recall-type monitor, preset a display mode on 
the waveform monitor, and then recall the mode 
externally. Switches on the AT board are used to 
select either recall type or 1730HD/1735HD type 
operation.
C TRUNK LINE connector (D-sub 9-pin, RS- 232C)
Used to connect the HDCU-900 to the 
TRACKER connector on an HDC-900 HD Color 
Video Camera via an RS-232C interface. Used 
mainly for communication with equipment on the 
camera side. The RXD, TXD, RTS, and CTS 
signals can be transferred at up to 19.2 kbps 
using this connector. 
D MIC REMOTE (microphone remote) connector 
(D-sub 15-pin)
Using this connector, the video camera’s 
microphone input level may be set by external 
equipment such as an audio mixer, in five steps 
(–60, –50, –40, –30, and –20 dB). When taping, 
set the volume to a level appropriate for the 
audio conditions.
E I/O PORT connector (D-sub 15-pin)
Used for remote control using an external 
control device.
Note
Use of a case wider than 42 mm can cause 
interference at connectors 2, 4, 5. It is 
recommended to use JAE-made DA-C1-J10.
d
CHARACTER OUTPUT connector (BNC type)
Used to output the results of the HDCU-900 diagnostic 
self-test in SD black and white analog video format.
e
DIGITAL AUDIO connector (BNC type)
Used to output a digital audio signal input to the 
camera.
f
MIC OUTPUT (microphone output) connectors 
(XLR 3-pin)
Used for output of the microphone input to the video 
camera.
g
INTERCOM/TALLY/PGM (program audio) 
connector (D-sub 25-pin)
Used for input and output of intercom, tally, and 
program audio signals. Connect to the intercom/tally/ 
program audio connector of the intercom system.
h
Expansion slot
For installation of the optional HKCU-901 SD Analog 
Interface Unit, HKCU-902 HD Analog Interface Unit, 
HKCU-903 Frame Rate Converter Unit, or HKCU-904 
Line Converter Unit.
7-3-3
HD Signal Input/Output Block
a
SERIAL RET INPUT 1-4 (HD-SDI return video 1, 
2, 3, and 4 input) connectors (BNC type)
Four different HD-SDI return video input signals may 
be received independently. The selection of RET 1, 2,
3, or 4 is made by the camera’s return switch. The type 
of input signal on RET 1, 2, 3, and 4 may be set 
individually using switches on the internal AT board, or 
using the MSU-700A/750 Master Setup Unit.
b
REFERENCE IN connectors (BNC type)
Used to input an HD tri-level reference sync signal or 
SD reference sync signal (black burst signal). If loop-
through output is not used, terminate the unused 
connector with 75 ohms.
Note
To use the VBS signal of the HKCU-901 (when SC 
phase lock is required), use an SD reference sync 
signal (black burst signal).
c
PROMPTER IN connectors (BNC type)
Used for prompter signal input. If loop-through output 
is not used, terminate the unused connector with 75 
ohms. If the signal used is a 1.0 Vp-p, 75-ohm signal, 
it may be output from the video camera PROMPTER 
OUT connector with a frequency bandwidth of 8 MHz, 
regardless of signal format.
d
SERIAL OUTPUT 1-3 (HD-SDI 1, 2, and 3 output) 
connectors (BNC type)
The signal from the video camera may be output as 
three HD-SDI signals.
e
SERIAL OUTPUT MONI (HD-SDI monitor output) 
connector (BNC type)
The signal from the video camera may be mixed with 
skin tone gate signals and some aspect marker signal 
and output in HD-SDI format.
1
 SERIAL RET INPUT 1-4 connectors
2
 REFERENCE IN connectors
3
 PROMPTER IN connectors
4
 SERIAL OUTPUT 1-3 connectors
5
 SERIAL OUTPUT MONI
     connector
1
2
3
4
1
2
3
MONI
SERIAL RET INPUT
REFERENCE IN
PROMPTER IN
SERIAL OUTPUT