Chapter 7 Location and Function of Parts and Controls
90
HDC-900/950/930 Series Product Information Manual
7-3-4
SD Signal Input/Output Block
These connectors can be replaced with the optional 
HKCU-902/903/904.
a
SERIAL RET INPUT 1-4 (SD-SDI return video 1, 2, 
3, and 4 input) connectors (BNC type)
Four different SD-SDI return video input signals may 
be received independently when the system is 
operating with the field frequency of 59.94/50 Hz. The 
selection of RET 1, 2, 3, or 4 is made by the camera’s 
return switch. The type of input signal on RET 1, 2, 3, 
and 4 may be set individually using switches on the 
internal AT board, or using the MSU-700A/750 Master 
Setup Unit. The aspect ratio may also be selected for 
SD signals.
b
SYNC OUT (HD/SD sync signal output) 
connector (BNC type)
Used for output of an HD tri-level sync or SD composite 
sync signal from the internal sync signal generator. 
(Factory setting: HD tri-level sync)
c
PIX OUT (picture monitor output) connector 
(BNC type)
Used for output of the picture monitor video signal 
selected using the RCP-700 series Remote Control
Panel MONITOR SELECT button, or the MSU-700A/
750 Master Setup Unit PICTURE MONITOR button. 
(When both the RCP and MSU are in use, this 
connector functions as the output connector for RCP 
control.)
d
WF OUT (waveform monitor output) connector 
(BNC type)
Used for output of the waveform monitor video signal 
selected using the RCP-700-series Remote Control
Panel MONITOR SELECT button, or the MSU-700A/
750 Master Setup Unit WF MONITOR button. (When 
both the RCP and MSU are in use, this connector 
functions as the output connector for RCP control.)
Note
The SC phase of the VBS signal output from 
connectors 3 and 4 is not locked to the black burst 
signal supplied to the REFERENCE IN connector. Use 
the monitor in Internal sync mode. 
e
WF MODE (waveform monitor mode) connector 
(4-pin)
Connect to the appropriate connector on a waveform 
monitor when monitoring a signal in sequential mode.
A sequence signal will be output when the SEQ button 
on the RCP-700 series Remote Control Panel is 
pressed, allowing simultaneous monitoring of the R, G, 
and B signals in sequential mode. (When both the RCP 
and MSU are in use, this connector functions as the 
output connector for RCP control.)
f
SERIAL OUTPUT 1-4 (SD-SDI 1, 2, 3, and 4 
output) connectors (BNC type)
When the system is operating with the field frequency 
of 59.94/50 Hz, the signal from the video camera may 
be down converted and output as four SD component 
SDI signals.
SYNC OUT
PIX OUT
WF OUT
1
2
3
4
1
2
3
4
SERIAL RET INPUT
SERIAL OUTPUT
WF MODE
1
 SERIAL RET INPUT 1-4 connectors
2
 SYNC OUT connector
3
 PIX OUT connector
4
 WF OUT connector
5
 WF MODE connector
6
 SERIAL OUTPUT 1-4 connectors