XDV Direct Vent Gas Fireplace
Optional Accessories Available
FK12 Fan Assembly
1.  Open louvre assembly bottom.
2.  Install FK12 fan in back of unit between hearth sup-
ports. (Fig. 90)
3.  Secure fan on velcro strips.
4.  Power to the fan can be supplied by plugging the 
supply lead into a conveniently located wall socket 
or by using a hard-wired EB-1 connector box.
5.  Be sure fan motor does not touch hearth supports.
FK24 Fan Assembly
Fan specifications: 120 volt, 60 Hz, .75 Amp.
This fan does not need regular maintenance, however 
periodic cleaning is required. Check the area under the 
control door and in front of the fan and wipe or vacuum 
at least once a month during the operating season. 
Should this fan require servicing, the power supply must 
be disconnected.
The FK24 comes with the electrical cord attached.
1.  Slide fan assembly from the left side into the fire-
place opening, line up mounting holes with screw 
studs on back of fireplace and fasten with #10 - 24 
hex nuts. (Fig. 91)
2.  Install thermal sensor on bottom of firebox using #10 
- 24 hex nuts.
3.  (Option A) - Place electronic fan speed control box 
on bottom of fireplace base, lining up mounting holes 
with screw studs. Fasten fan speed control box with 
#10 - 24 hex nuts.
  (Option B) - The speed control can be installed in an 
electrical box at normal wall switch height for conve-
nient access.
4.  The power supply may be connected in 2 ways:
Method A
  Route the 6’ (1.8m) lead fitted to the unit to a conve-
niently located wall socket.
Method B
  If the EB-1 receptacle box (Pt. #ZA1200) was cor-
rectly connected when the unit was installed, the 
fan lead can be directly plugged into the EB-1 plug 
socket.
5.  Whether wiring directly to the fan junction box (Op-
tion A) or into the EB1 (electrical box, Option B) first 
ensure cable is secured using box connector.
The fireplace, when installed must be 
electrically connected and grounded in ac-
cordance with local codes, with the current 
CSA C22.1 Canadian Electrical Code or for 
US installations, follow local codes and the 
National Electrical Code, ANSI/NFPA No. 
70.
Hard (Direct) Wire Hook Up
First connect ground wire to ground stud located on 
the base of either box. Black wire from supply should 
connect to the variable speed switch. Alternate speed 
switch wire connects to temperature sensor. Alternate 
lead from sensor connects to fan. Alternate fan lead 
connects back to the white supply wire. (Fig. 92)
Any electrical rewiring of this fan must be 
completed by a qualified electrician.
Turn off all power before hook up.
Fan Kits
FP1004
Fan placement
DV360/580 Series
1/25/00   djt
Cold Air Box
Side View
Front of 
Unit
Hearth Pan
Base Pan
FK12 Fan
FP1004
Fig. 90  FK12 Fan Kit placement.
Black
White
Ground
FP394
WIRING DIAGRAM
11/20/96
Fan
Temperature 
Sensor
Speed 
Control
FP1025
Fig. 92  FK24 fan wiring.
  
HI 
   
  
  
  
   
 LO 
     
     
   
  
ON
   
  
  
  
  
    OFF
   
E
A
  P
ILO
TP
TH
FP1026
FK24
fan placement
1/27/00   djt
Electrical Box
Heat Sensor
Fan
Valve
Gas Line
Fan Speed 
Switch
Fig. 91  FK24 fan placement.
FP1026