Vermont Casting 36XDV User Manual

Page of 56
XDV Direct Vent Gas Fireplace
50
10009383
Remote Controls
Optional remote control units are available to control dif-
ferent functions of the appliance. (For use on R Models)
 
Model 
Functions Controlled
 
RC1 
ON/OFF
 
RC2 
ON/OFF and Temperature
 
IMTFK 
Wall mounted thermostat control
Ceramic Refractory Panels
 
Unit 
 Kit Model and Finishings
 
 
Sandstone 
Red 
Black 
Grey
  33XDV 
GAHC3I0 
GAFC3I0  GABC3I0  GAGC3I0
  36XDV 
GAHC3J0 
GAFC3J0  GABC3J0  GAGC3J0
  39XDV 
GAHC3K0 
GAFC3K0  GABC3K0  GAGC3K0
Take care when handling the refractory 
panels as they are fragile until held in place 
and supported.
Installation Instructions
1.  Remove window frame assembly and logs.
2.  Remove three (3) screws securing heat shield to 
combustion dome. (Fig. 93)
3.  Place rear ceramic panel in back of unit. (Fig. 94)
4.  Place side panels.
5.  Re-install heat shield, logs and window frame as-
sembly.
H103
heat shield
3/1/99   djt
Heat Shield
Section A
Heat 
Shield
(3) 
Screws
Side View 
Section A
H103
Fig. 93   Heat shield.
H102
rear ceramic support
2/23/99   djt
Rear 
Ceramic Panel
Burner
Back of 
Firebox
Rear Log 
Support
H102
Fig. 94  Rear ceramic panel placement.